5
PROBLEMS AND SOLUTIONS
MINIDUMPER
CARRY 105EP
34
The electrical power supply is fitted with control and diagnostics circuits: any faults are marked on the display
with an error code. Please use the table following to interpret the error codes:
SIGN
PROBABLE CAUSE
REMEDY
A-2083 EXCESSIVELY HIGH TEMP (AT START-UP).
Turn off the machine, let
it cool and try again.
A-2055
EXCESSIVELY HIGH TEMP IN ONE OR MORE CELLS (MACHINE IN
OPERATION).
Turn off the machine, let
it cool and try again.
A-2058
EXCESSIVELY HIGH TEMP IN THE BMS (MACHINE IN
OPERATION).
Turn off the machine, let
it cool and try again.
A-2018
EXCESSIVELY HIGH TEMP IN ONE OR MORE CELLS (MACHINE IN
RECHARGE MODE).
Turn off the machine, let
it cool and try again.
A-2023
EXCESSIVELY HIGH TEMP IN THE BMS (MACHINE IN RECHARGE
MODE).
Turn off the machine, let
it cool and try again.
A-2244 EXCESSIVELY LOW NETWORK VOLTAGE.
Check
the
network
voltage.
A-2248
INTERNAL TEMP OF THE BATTERY CHARGER EXCESSIVELY
HIGH.
Turn off the machine, let
it cool and try again.
A-2253 EXCESSIVELY HIGH NETWORK VOLTAGE.
Check
the
network
voltage.
A-2000 EQUALIZATION IS REQUIRED.
Connect the machine in
charge
until
the
equalization end (The
display
shows
the
message FINISH).
For all the other alarms, contact the support service.
5.2
SPARE PARTS
R
EPLACE WORN OR DAMAGED PARTS WITH ORIGINAL
KATO
IMER
SPARE PARTS
.
U
SING NON
-
ORIGINAL SPARE PARTS COULD CAUSE INJURY TO THE OPERATOR OR DAMAGE TO THE MACHINE
.
KATO
IMER
DECLINES ALL LIABILITY FOR ANY DAMAGE CAUSE BY NON
-
ORIGINAL PARTS THAT HAVE NOT BE
EXPLICITLY APPROVED
.
WARNING
I
T IS FORBIDDEN TO MAKE CHANGES OF ANY SORT TO THE STRUCTURE AND THE PLANT DESIGN OF THE
MACHINE BECAUSE THIS MAY COMPROMISE ITS SAFE USE
.
.
WARNING
Содержание CARRY 105 ELECTRIC POWER
Страница 2: ......
Страница 27: ...3 USER INSTRUCTIONS MINIDUMPER CARRY 105EP 18 3 6 SET UPS TRUCK BED LOAD BODY WITH SHOVEL LOAD BODY ...
Страница 47: ...TRACKED MINIDUMPER CARRY 105 ELECTRIC POWER PUBLISHED MARCH 2017 KATO IMER S p A ITALY ...
Страница 48: ......