936.3224/A/1207/24.68e
“Cable NIT” sub-menu
****
Cable NIT
****
NIT:
off
Generate
Network:
Name ID
“Cable NIT” sub-menu (display during NIT generation)
Cable NIT is
being generated
Please wait
□
□
□
□
...
A B C E D E F G H I J K L M N O P Q R
S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9 _
KATHREIN WERKE KG _
“Name” sub-menu
“ID” sub-menu
Network ID
FF 01
2.3.1
Setting the name and the network ID for the cable NIT
Press the “<” and “>” buttons to select the desired parameter “on”, “Generate”, “Name” or “ID”.
Press the “Sub-menu” button to activate the selected parameter and open the respective sub-menu.
The network name is set by adding “+” or removing “-” characters at the fl ashing cursor in the third (name) line. The character
to be added is selected by using the “<” and “>” buttons to move the cursor within the fi rst two lines. The maximum number of
characters is 40.
Exit the menu by pressing the “Sub-menu” button; this saves the set value.
The network ID should only be set if the operator applied for and was granted the ID by the ETSI.
The preset value (FF01) is intended for networks without a specifi c network ID.
The network ID is selected digit-by-digit using the “<” and “>” buttons and is changed using the “+” and “-” buttons.
Exit the menu by pressing the “Sub-menu” button; this saves the set value.
2.3.2
Generating the cable NIT, switching the cable NIT on and off
The controller completes the
NIT generation process
after it is started
manually with the “+”
button.
The new cable NIT is created and then sent to the channel units (with QAM output). The procedure can be aborted by pressing
the “-” button (leading to the error message shown below). A progress bar is displayed in the bottom line of the display during
the generation process.
When the cable NIT is complete it is saved and can now be switched on and off as required. This is done by using the “<” and
“>” buttons to select the “Cable NIT” “on/off” sub-menu and using the “+” and “-” to make the change-over.
The following error messages may appear during cable NIT generation:
“Cable NIT” sub-menu
NIT error
Not all channel
units registered
< Further: Button >
“Cable NIT” sub-menu
NIT error:
Insert position specifi -
cation not satisfi ed
< Further: Button >
“Cable NIT” sub-menu
****
Cable NIT
****
NIT:
on
Generate
Network:
Name
ID
“Cable NIT” sub-menu (display during abort)
NIT error:
User abort
<Further: Button>
Содержание UFO 372/TP
Страница 66: ...936 3224 A 1207 66 68d ...