Configuration manual Reader
23
Modifications, misprints and errors excepted.
English
2.
Description of the configuration parameters
Important!
Since there are frequencies which the hardware of the RFID reader cannot deliver, when using the “Special”
communications standard, a spectrum analysis must be performed to check whether each channel frequency is
available for the correct setting.
2.8.1.
“CenterFreqCH0”
Characteristics:
available from firmware:
v1.32.00
Data type:
DWord (32-bit)
Unit:
kiloHertz
Value range:
0-1048575
Description:
This configuration parameter specifies the mid-frequency of channel 0 for the “Specia” communications standard.
2.8.2.
“ChannelWidth”
Characteristics:
available from firmware:
v1.32.00
Data type:
Word (16-bit)
Unit:
kiloHertz
Value range:
0-65535
Description:
This configuration parameter allows the width of each radio channel for the “Special” communications standard
to be specified.
2.8.3.
“MaxChannelTime”
Characteristics:
available from firmware:
v1.32.00
Data type:
Word (16-bit)
Unit:
milliseconds
Value range:
0; 10-65535
Description:
This configuration parameter for the “Special” communications standard specifies how long the reader may occupy a
selected channel until it must change to the next channel.