background image

Configuration manual Reader 

18

Modifications, misprints and errors excepted.

English

2. 

Description of the configuration parameters

2.4.16. 

“DisableReceivingNXPReadProtectedTags”

Characteristics:

available from firmware:

v2.01.00

Data type:

Bool (8-bit)

Unit:

Value range:

0; 255

Description:
If  a  tag  from  the  company  NXP  was  protected  by  “ReadProtect”,  at  inventory  it  would  no  longer  communicate 

its  EPC  or  a  valid  checksum.  The  data  content  of  the  EPC  and  the  checksum  is  zero.  To  allow  such  tags  to  be 

detected,  the  reader  allows  tags  for  which  the  EPC  and  checksum  are  zero  to  pass.  Since  such  tags  are  no 

longer  secured  with  a  valid  checksum,  it  can  happen  very  occasionally  that  the  reader  detects  such  a  tag  where 

none exists. In order to prevent this, the reception of “ReadProtected” tags can be suppressed by activation of this  

configuration parameter.

2.5. 

The configuration group “ObservedList”

2.5.1. 

“GlimpsedTimeoutCnt”

Characteristics:

available from firmware:

v1.30.00

Data type:

Byte (8-bit)

Unit:

Value range:

0-255

Description:
This  configuration  parameter  applies  only  to  asynchronous  protocol  commands  (“ASync...”).  For  the  duration 

of  an  asynchronous  command,  the  reader  compiles  a  list  of  all  the  tags  found  within  the  antenna  range.  If  a  tag 

is  present  in  the  antenna  range  for  multiple  inventories,  a  “coming”  message  is  generated  for  that  tag  and  the 

message is sent to the higher level. If a tag is no longer detected during multiple inventories, a “going” message is  

generated and sent.
Once  the  “going”  message  has  been  generated  for  a  tag,  this  configuration  parameter  specifies  the  number  of 

inventories where the tag is not detected, which then triggers deletion of this tag from the internal administration list. 

This parameter should not be changed. It has no influence over the generation of a “coming” or “going” message.  

Kathrein reserves the right to remove this parameter from firmware versions at a future point in time.

2.5.2. 

“ObservedThresholdCnt”

Characteristics:

available from firmware:

v1.30.00

Data type:

Byte (8-bit)

Unit:

Value range:

0-255

Description:
This  configuration  parameter  applies  only  to  asynchronous  protocol  commands  (“ASync...”).  For  the  duration 

of  an  asynchronous  command,  the  reader  compiles  a  list  of  all  the  tags  found  within  the  antenna  range.  If  a  tag 

is  present  in  the  antenna  range  for  multiple  inventories,  a  “coming”  message  is  generated  for  that  tag  and  the 

message is sent to the higher level. If a tag is no longer detected during multiple inventories, a “going” message is  

generated and sent.
This configuration parameter specifies the number of inventories where the tag is detected, which then triggers the 

generation of a “coming” message which is sent to the higher level.

Содержание RRU 4 series

Страница 1: ...r all Kathrein RFID reader and describes the configurationspharameter that are necessary to operate the reader Although reference is made in the text to RRU4 respect with the same commands can be cont...

Страница 2: ...M ARU RS232 FCC 52010136 M ARU ETH E6 52010198 M ARU ETH U6 52010199 RFID UHF Reader This manual applies to the following RRU4 types Type Order number RRU4 RS4 E6 52010093 RRU4 ETG E6 52010094 RRU4 ET...

Страница 3: ...the reader Scope The information contained in this manual is intended for the support of the development process and as development guidance for the customer In addition this manual offers supporting...

Страница 4: ...e configuration parameters of the RRU4 reader system 6 2 1 The Global configuration group 6 2 2 The configuration group RFInterface 6 2 3 MultiplexingExposureTime1 8 9 2 4 The configuration group Tag...

Страница 5: ...alue For ease of handling the configuration parameters are addressed by their plain text names The plain text name begins with cfgid followed by the name of the configuration group This includes the f...

Страница 6: ...2 2 The configuration group RFInterface 2 2 1 RFPower1 8 Characteristics available from firmware v1 30 00 Data type Byte 8 bit Unit dBm erp Value range 0 68 136 Description This parameter allows the...

Страница 7: ...by the reader and the next inventory command is received within the time configured by this parameter the reader can dispense with the LBT and the antenna test and start the inventory more quickly No...

Страница 8: ...t of the reader Either an antenna port number 1 to 8 or a zero can be entered in each of the eight list slots If a zero is entered the list slot is deactivated and the reader skips to the next list sl...

Страница 9: ...interrupted at the expiry of the exposure time but is continued to completion 2 3 1 CableLoss1 8 Characteristics available from firmware v1 30 00 Data type Byte 8 bit Unit dB Value range 0 255 Descri...

Страница 10: ...e threshold setting are then no longer detected by the reader 2 3 4 MultiPowerTagAccess1 8 Characteristics available from firmware v1 30 00 Data type Bool 8 bit Unit Value range 0 255 Description The...

Страница 11: ...the RSSI value of the tag is fluctuating around the threshold value In such a scenario EnableRSSIThresholdAtSpecificCmds should be deactivated 2 3 7 FlashWriteAdditionalPower Characteristics available...

Страница 12: ...conds This configuration parameter instructs the reader the session with which it should work Characteristics available from firmware v1 30 00 Data type Byte 8 bit Unit Value range 0 15 Description Th...

Страница 13: ...reader communication the coding of the data from tag to reader There are various data transmission rates data reception rates and codings available Since not every combination of these three properti...

Страница 14: ...e tag with IntelligentWrite activated no error message is generated by the reader No write command is issued to the tag in the process of reading the existing data comparing it with the data to be wri...

Страница 15: ...tags should participate in the inventory If the configuration parameter has the value zero the tags participate in the inventory for which the inventoried flag is set to A Otherwise only the tags for...

Страница 16: ...he protocol commands SyncGetEPCs SyncBulkGetEPCs ASyncGetRawEPCs and ASyncGetEPCs All other protocol commands behave as if TransmitGetEPCsPreSelect is zero Depending on the value of this configuration...

Страница 17: ...configuration parameter can be used to specify whether or not before the inventory a select command should be sent to perform a global reset of all tags within the antenna range 2 4 14 NumberOfEPCWord...

Страница 18: ...in the antenna range for multiple inventories a coming message is generated for that tag and the message is sent to the higher level If a tag is no longer detected during multiple inventories a going...

Страница 19: ...ion This configuration parameter allows specification of which additional information on a tag should be sent when tag data are sent to the higher level Every bit of the lower four bits that is set to...

Страница 20: ...ation scenarios it is of interest to view how the field strength RSSI value of a tag behaves in the time between the coming message and the going message This allows amongst other things conclusions t...

Страница 21: ...er selects a channel from this channel list at random for communication with the tags 2 7 3 ChannelSwitchingMode Characteristics available from firmware v1 30 00 Data type Byte 8 bit Unit Value range...

Страница 22: ...0 1 Watt since within these channels channel 3 has a maximum power setting of only 0 1 Watt 2 If point 1 yields a maximum power setting of 0 Watt if for instance EN302208 was selected and a channel ot...

Страница 23: ...048575 Description This configuration parameter specifies the mid frequency of channel 0 for the Specia communications standard 2 8 2 ChannelWidth Characteristics available from firmware v1 32 00 Data...

Страница 24: ...ailable from firmware v1 32 00 Data type Byte 8 bit Unit Value range 0 255 Description This configuration parameter for the Special communications standard specifies the first channel to be used for t...

Страница 25: ...nglish 3 List of references communication protocol A for software developers configurational manual reader B for commissioning installation manual reader C Setup and installation installation manual a...

Страница 26: ...ntact Kathrein RFID E Mail rfid sales kathrein sachsen de Am Kroit 25 27 Internet www kathrein rfid de D 83123 Amerang 4 Contact address Configuration manual Reader 26 Modifications misprints and erro...

Отзывы: