5 / 8
Only use splitters without diodes (EBC 110 or EBC 114). The required diode
protection is provided by outlets from the ESU series.
It is especially important to make sure that each userband is assigned only
once, since otherwise the receivers will generate mutual interference. The
frequencies are allocated on the receivers settings menu. Depending on the
type, this may be performed manually or automatically.
It is recommended that the wall sockets with the shorter length connections
are assigned to the higher frequencies. By de
fi
nition the system is designed so
that single-cable units are supplied with 14 V DC. The power supply is brie
fl
y
switched to 18 V DC if control signals similar to DiSEqC™ have to be transmit-
ted. Continuous application of 18 V would block the system. For this reason we
recommend the use of ESU series outlets, which are equipped for switching off
electronically.
The receivers that are connected must be designed for single-cable opera-
tion conforming to EN 50494. In order to use userband 9, the receiver must
also support the single-cable standard SCD2 as per prTS 50607.
Notes