Technical Appendix
99
Command overview command byte
Hex-
byte
Command
identification
Description
Number
Data/ Byte
00
Reset
Reset DiSEqC minicontroller
-
01
Clr. Reset
Reset flag clear
-
02
Standby
Switches off the peripheric power supply unit
-
03
Power on
Switches on the peripheric power supply unit
-
04
Set Contend
Sets the contention flag
-
05
Contend
Feedback only when contention flag is set
-
06
Clr. Contend
Clears contention flag
-
07
Adresse
Feedback only when contention flag is not set
-
08
Move C
Which address when contention flag is set
1
09
Move
Which address when contention flag is not set
1
10
Status
Reads status-register flags
-
11
Config.
Reads configuration flags
-
14
Switch 0
Reads switching status flags (committed port)
-
15
Switch 1
Reads switching state flags (uncommitted port)
-
16
Switch 2
Expansion option
-
17
Switch 3
Expansion option
-
20
Set LO
Calls up the low local oscillator frequency
-
21
SET VR
Calls up the vertical polarisation or circular polarisation , clockwise
-
22
Set Pos A
Selects satellite position A
-
23
Set S0A
Selects switch option A
-
24
Set Hi
Calls up the high local oscillator frequency
-
25
Set HL
Calls up the horizontal polarisation or circular polarisation, counter-clockwise
-
26
Set Pos B
Selects satellite position B
-
27
Set S0B
Selects switch option B
-
28
Set S1A
Calls up matrix S1 input A (input B inactive)
-
29
Set S2A
Calls up matrix S2 input A (input B inactive)
-
2 A
Set S3A
Calls up matrix S3 input A (input B inactive)
-
2 B
Set S4A
Calls up matrix S4 input A (input B inactive)
-
2C
Set S1B
Calls up matrix S1 input B (input A inactive)
-
2D
Set S2B
Calls up matrix S2 input B (input A inactive)
-
2E
Set 3SB
Calls up matrix S3 input B (input A inactive)
-
2F
Set S4B
Calls up matrix S4 input B (input A inactive)
-
30
Sleep
All bus-commands are ignored except „Awake“
-
31
Awake
Bus-commands are accepted again
-
38
Write N0
Sets port group 0
1
39
Write N1
Sets port group 1
1
3A
Write N2
Expansion option
3B
Write N3
Expansion option
1
40
Read A0
Reads analogue value A0
-
41
Read A1
Reads analogue value A1
-
48
Write A0
Sets analogue value A0
1
49
Write A1
Sets analogue value A1
1
4F
Write A7
Sets analogue value A7
1
50
LO string
Reads current frequency
-
51
LO now
Reads current frequency (Table entry number)
-
52
LO Lo
Reads low frequency table entry number
-
53
Lo Hi
Reads hi frequency table entry number
-
58
Write Freq
Writes channel frequency
2 or 3
59
Ch.No.
Sets the selected channel number (Receiver)
2
60 Halt
Stops
positioner
-
61
Go E
Directs positioner to the east
-
Go W
Directs the positioner to the west
62
64
P Status
Reads positioner status register
-
65
Read Pos
Reads positioner counter
-
6C
Goto
Drives positioner motor to counter value hi, low
2
6D
Write Pos
Set positioner counter hi, low
2
In the MSK 33, two different DiSEqC types have integrated. DiSEqC 1.0: With this system, DiSEqC commands can be sent but not
received. DiSEqC 2.0: With this system, DiSEqC commands can be sent and received (highlighted in grey in the table). Bold com-
mands are preferably used for Kathrein switching matrices.
Содержание 9986492
Страница 1: ...Operating manual Sat TV FM Test Receiver MSK 33 Software version 8 3 December 2002...
Страница 2: ...2...
Страница 114: ...Notice 114 Notice...