Technical Appendix
98
Technical Appendix
Overview of DiSEqC commands
Command overview framing byte
Hex-byte
Description
E0
Commando from master, one time transmission
E1
Commando from master, repeated transmission
E2
Commando from master, answer expected, first transmission
E3
Commando from master, answer expected, repeated transmission
E4
Answer from slave, „OK“, no error detected
E5
Answer from slave, commando is not supported by slave
E6
Answer from slave, parity error is detected
E7
Answer from slave, commando not recognised
Command overview address byte
Hex-byte
Description
00 All
units
10
Each LNB, Matrix or SMATV
11 LNB
12
LNB with loop-through
14 Matrix
(Switcher)
15
Matrix (Switcher) with loop-through
18 SMATV
20 Every
polarizer
21
Full skew for linear polarisation
22
Polarizer gradually set
30 Every
positioner
31
Polar / azimuth positioner
32 Elevation
positioner
33 Combined
positioner
34 LNB
positioner
40 Installations-help
41
Signal strength setting-help
60
Reserved for assigned addresses
70
„Intelligent slave interface“ for „Proprietary Multy-Master bus“
71
Interface for subscriber and controlled head ends
Fx CEM
extension