Sat Operation
27
SCAN
With the function
SCAN
, satellites can be searched for, whose transponder fre-
quencies are not known. Here, the frequency range of 920 to 2150 is continuously
scanned for the receiving signals. If the receiving signals are available, the recep-
tion level is displayed on the screen as a bar diagram. Four measurement ranges
with the dynamic of each 40 dB are available for the bargraph display. The meas-
urement range is automatically preselected.
Bargraph
display
Level range
Comment
I
30-70 dBµV
Automatic range change at 70 dBµV
II
50-90 dBµV
Auto. range change at 50 and 90 dBµV
III
70-110 dBµV
Auto. range change at 70 and 110 dBµV
IV
90-130 dBµV
Automatic range change at 90 dBµV
The level can be controlled with an acoustic signal. The frequency of the acoustic
signal varies in proportion with the receiving signal level. The volume of the acous-
tic signal can be changed.
The screen shows the bargraph display, which changes in
proportion with the input signal.
The field SCAN lights up yellow, as soon as the softkey is pressed. The entire Sat
frequency range is now scanned. By pressing the button once more, the process is
stopped and the softkey display changes to “scan off.“
Calling up menu LNB-CONTROL
In this menu, all LNB parameters can be set, for example, remote power feeding
voltage H/V, 22-kHz-, DiSEqC-, V-SEC signal, UFOµ DiSEqC as well as LO fre-
quency.
Switch-over of ANALOG digit. DVBS
Calling up the menu SAT MEASURE
In this menu, all Sat receiving parameters for the reception of digital or analogue
signals can be set and the measurements can be carried out. Calls up the MPEG-
Decoders for digit. DVB-S.
LNB
CONTROL
digit.
DVBS >
SAT
MEASURE
analog
>