13
Manual Operation
Manual operation of the
PowerSurvivor 40E
is
useful if the ship’s electric power supply fails. Use
the following instructions to convert your
watermaker to manual operation:
1.
Jog run the watermaker and stop it when
the piston has traveled the maximum
distance away from the pump, toward the
drive assembly.
2.
If necessary, disconnect the seawater
intake, reject brine, and product
freshwater hoses (
Figure 5
) and move the
watermaker to a location convenient for manual operation.
3.
Slide the black rubber boot on the piston shaft
toward the pump to expose the coupling pin.
Pull or tap out the coupling pin which connects
the pump piston shaft to the drive slider shaft
(
Figure 6
). The pin is a fairly loose fit and
should come out easily. Be careful not to lose
it!
4.
Using a 1/2" wrench, remove the four hex
nuts holding the pump body to the drive
assembly. Separate the drive assembly from
the pump body and set the drive unit aside. Remove the black rubber boot from the piston
shaft.
5.
Align the holes in the handle bracket with the two pump bolts that are located above the
piston shaft (
Figure 7
). Slide the bracket over the bolts and secure it with two of the hex nuts
that held the drive assembly to the pump body. Do not over tighten these nuts.
6.
Remove the clevis pin from the free end of the linkage attached to the handle assembly. Line
up the holes in the handle linkage with the hole in the piston shaft. Insert the clevis pin
through the linkage and the piston shaft and secure with a split ring (
Figure 8
).
7.
Orient the hole in the handle (located above the linkages) between the holes in the handle
bracket. Insert the second clevis pin through the holes and secure with the split ring
(
Figure 9
).
8.
If not already attached, connect seawater intake, reject brine, and product freshwater hoses
to be used for manual operation.
Содержание PowerSurvivor 40E
Страница 1: ...PowerSurvivorTM 40E 12 Volt 24 Volt Watermakers OWNER S MANUAL ...
Страница 30: ...30 Diagrams ...
Страница 31: ...31 Kit Spool Valve 8018615 8016525 ...
Страница 32: ...32 ...
Страница 33: ...33 ...
Страница 35: ...35 Service Log Date Preserved Membrane Cleaned Membrane Other Service ...