Installation requirements of components
Filter Unit:
•
Stable positioning
•
Comfortable operational height for water delivery and filter cleaning
•
Intake position / filter: Static suction lift < 5 meters
•
Positioned near best water quality if possible
•
Placement on a dry surface
Filter Connection:
•
Pump inlet 2” (suction hose and intake filter are enclosed)
•
Filter fresh water outlet ¾”
•
Drain water
outlet ¾”
•
Cleaning hose connection ½” (hose is enclosed)
•
Sample valve outlet ¼”
3.7
Flow rates of the MOT-7
The above chart shows the typical performance of the unit when operated in the standard operating
conditions described in this manual. Increasing the static resistance of the system will reduce the
volume of treated water. Optimal positioning of
the intake hose (reducing dirt intake) increases the
performance of the
MOT- 7.