background image

 

 

 

 

Pump Honda 

WH 20X

 

 

 

 

 

WH 20X 

– extremely sturdy

 

The high-pressure pumps of the WH series are outfitted with the most durable and long- 
lasting Honda G X engines. The powerful engine and especially sturdy housing enable 
strong water delivery pressures with a water capacity of up to 500 liters per minute.  

Capacity (l/min)

 

500

 

Capacity (m³/h)

 

30

 

Static suction lift

 

8  m

 

Port diameter

 

2

 

Motor type

 

OHV  GX 160

 

Rated output

 

3.6 kW

 

Rated  speed

 

3600 U/min

 

Tank Capacity

 

3.1 L

 

Consumption (l/h)

 

1.6

 

Measurements  (LxWxH) 

435 x 375 x 400 mm

 

Weight

 

23.5 kg

 

 
 

 

Please refer to the accompanying Honda Manual regarding the correct handling of the 
high-pressure pump WH 20X. Both this manual and the manual from Honda must be 
read and completely understood. 
 

Your safety depends on it! 

 

 

 

4.1 

Setup Procedure 

 
 

Check the oil and fuel types and levels  according to the Honda Handbook. 

 

 

Connect the suction hose for untreated water to the 
pump and position the intake filter in the

 

water at 

the intended site based on the description in the 
operating instructions. 

 
 
 
 
 
 
 
 

 
 

 

Содержание MOT-7

Страница 1: ...1 MobileMicrofiltrationSystem MOT 7 Water treatment with Katadyn ceramic filters...

Страница 2: ...entration 7 3 6 Installation requirements of components 8 3 7 Flow rates of the MOT 7 8 4 1 Setup Procedure 9 5 1 Setup procedure 10 6 1 Brief description of the handle position of operational compone...

Страница 3: ...eral Safety Guidelines The mobile Microfiltration System MOT 7 from Katadyn has been factory tested The dangers of improper use or failing to follow the operating procedures outlined in this manual ma...

Страница 4: ...in this supplement Only when these are followed without exception can operators and others avoid the loss of life and serious injuries or avoid interference with the system s operation or other materi...

Страница 5: ...safety operations and maintenance instructions and improper repairs Improper use of the MOT 7 use not in compliance with instructions Use of repair parts not permitted by the MOT 7 manufacturer Opera...

Страница 6: ...filters are made from various natural raw materials of the highest quality standard As such we can attain a nominal pore size of 0 2 m with insignificant variations 3 2 Primary features of mobile micr...

Страница 7: ...ments become dirtier the flow rate also decreases accordingly Intervals between cleanings can be influenced positively with the appropriate placement of the suction hose Placing the hose directly unde...

Страница 8: ...resh water outlet Drain water outlet Cleaning hose connection hose is enclosed Sample valve outlet 3 7 Flow rates of the MOT 7 The above chart shows the typical performance of the unit when operated i...

Страница 9: ...6 kW Rated speed 3600 U min Tank Capacity 3 1 L Consumption l h 1 6 Measurements LxWxH 435 x 375 x 400 mm Weight 23 5 kg Please refer to the accompanying Honda Manual regarding the correct handling o...

Страница 10: ...ice 5 1 Setup Procedure Take care that the filter unit is placed in a stable position and that the location surface is dry Remove the No 5 filter elements from the package and screw them hand tight in...

Страница 11: ...11 Hook up the cleaning hose to the corresponding threads The MOT 7 is now ready for use...

Страница 12: ...t Valve B Sample Valve E Open Close 6 2 Filling Venting Check that all valves are closed Start the motor and vent the pump Turn the main valve A counter clockwise to open Open vent valve B just slight...

Страница 13: ...g 6 5 Water Sampling Sampling must be performed by an experienced person according to DIN EN 25667 2 procedures The mobile Microfiltration System MOT 7 must be set in the operational mode see chapter...

Страница 14: ...lve D as soon as the filter elements are standing in water by 1 6 only Put the cleaning brush over the filter element and move it up and down 6 8 times and at the same time flush with water from the p...

Страница 15: ...the Pump Open cleaning valve C Clean the filter elements and inside of the housing with the cleaning hose Close cleaning valve C Stop the Pump Open the drain valve D and empty the filter housing Repla...

Страница 16: ...se the sampling valve Pump unit delivers too little water Motor is not running at the max speed Suction filter not completely covered in water or dirty Optimize the suction filter Clean the filter Suc...

Страница 17: ...t Number Description Picture 7010719 V Band Clamp M MOT7 MF 7 20621 SET Cleaning Hose M MOT7 complete 20616 Cleaning Brush for Katadyn Filter elements 20335 Measurement gauge for Katadyn Filter elemen...

Страница 18: ...tadyn Filter element No 5 128031 O Ring Seal 268 x 16mm 7010633 Suction Hose M MOT7 incl coupling to Pump 20615 1 Pair of Brush Segments Nylon 20619 1 Pair of Brush Segments Bronze Option for difficul...