background image

 

14 

 

 

 

 

Maintenance and Service 

 
 

 

7.1 

Honda Handbook reference 

 

Please refer to the accompanying Honda Manual regarding the correct handling of the high-pressure

 

pump 

WH  20X.  Both  this manual  and  the  manual from Honda  must  be  read  and  completely

 

understood. Your 

safety depends on it! 

 

 

7.2 

Cleaning the filter elements 

 

 

Turn off the pump 

 

Close the main valve A 

 

Open vent valve B 

 

Open the drain valve D (emptying) 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Open the clamp ring and remove the cover 

 

Close the drain valve D as soon as the filter elements are 
standing in water by 1/6 only. 

 
 
 
 
 
 
 

 

 

Put the cleaning brush over the filter element and move it up and down 6-8 times 
and, at the

 

same time, flush with water from the pump (For this process, water 

must  not  be  filtered).

 

Repeat  the  process  as  needed  until  the  surface  of  the 

filter  element  is  clean.  In  addition  to

 

the  dirt  particles  that  will  be  removed, 

some  of  the ceramic  will  also  be  rubbed  off  in  the

 

process. That is completely 

normal  and  desirable.  In  that  way,  you  will  be  assured  that  the

 

filter element 

has totally new filter characteristics when cleaning is completed. 

 

Repeat the above procedure on all filter elements. 

 
 
 

 

 

 

A

D

C

Содержание MOT-7

Страница 1: ...1 MobileMicrofiltrationSystem MOT 7 Water treatment with Katadyn ceramic filters...

Страница 2: ...entration 7 3 6 Installation requirements of components 8 3 7 Flow rates of the MOT 7 8 4 1 Setup Procedure 9 5 1 Setup procedure 10 6 1 Brief description of the handle position of operational compone...

Страница 3: ...eral Safety Guidelines The mobile Microfiltration System MOT 7 from Katadyn has been factory tested The dangers of improper use or failing to follow the operating procedures outlined in this manual ma...

Страница 4: ...in this supplement Only when these are followed without exception can operators and others avoid the loss of life and serious injuries or avoid interference with the system s operation or other materi...

Страница 5: ...safety operations and maintenance instructions and improper repairs Improper use of the MOT 7 use not in compliance with instructions Use of repair parts not permitted by the MOT 7 manufacturer Opera...

Страница 6: ...filters are made from various natural raw materials of the highest quality standard As such we can attain a nominal pore size of 0 2 m with insignificant variations 3 2 Primary features of mobile micr...

Страница 7: ...ments become dirtier the flow rate also decreases accordingly Intervals between cleanings can be influenced positively with the appropriate placement of the suction hose Placing the hose directly unde...

Страница 8: ...resh water outlet Drain water outlet Cleaning hose connection hose is enclosed Sample valve outlet 3 7 Flow rates of the MOT 7 The above chart shows the typical performance of the unit when operated i...

Страница 9: ...6 kW Rated speed 3600 U min Tank Capacity 3 1 L Consumption l h 1 6 Measurements LxWxH 435 x 375 x 400 mm Weight 23 5 kg Please refer to the accompanying Honda Manual regarding the correct handling o...

Страница 10: ...ice 5 1 Setup Procedure Take care that the filter unit is placed in a stable position and that the location surface is dry Remove the No 5 filter elements from the package and screw them hand tight in...

Страница 11: ...11 Hook up the cleaning hose to the corresponding threads The MOT 7 is now ready for use...

Страница 12: ...t Valve B Sample Valve E Open Close 6 2 Filling Venting Check that all valves are closed Start the motor and vent the pump Turn the main valve A counter clockwise to open Open vent valve B just slight...

Страница 13: ...g 6 5 Water Sampling Sampling must be performed by an experienced person according to DIN EN 25667 2 procedures The mobile Microfiltration System MOT 7 must be set in the operational mode see chapter...

Страница 14: ...lve D as soon as the filter elements are standing in water by 1 6 only Put the cleaning brush over the filter element and move it up and down 6 8 times and at the same time flush with water from the p...

Страница 15: ...the Pump Open cleaning valve C Clean the filter elements and inside of the housing with the cleaning hose Close cleaning valve C Stop the Pump Open the drain valve D and empty the filter housing Repla...

Страница 16: ...se the sampling valve Pump unit delivers too little water Motor is not running at the max speed Suction filter not completely covered in water or dirty Optimize the suction filter Clean the filter Suc...

Страница 17: ...t Number Description Picture 7010719 V Band Clamp M MOT7 MF 7 20621 SET Cleaning Hose M MOT7 complete 20616 Cleaning Brush for Katadyn Filter elements 20335 Measurement gauge for Katadyn Filter elemen...

Страница 18: ...tadyn Filter element No 5 128031 O Ring Seal 268 x 16mm 7010633 Suction Hose M MOT7 incl coupling to Pump 20615 1 Pair of Brush Segments Nylon 20619 1 Pair of Brush Segments Bronze Option for difficul...

Отзывы: