Page 32
Katadyn
15.6
Short Circuit
Short Circuit
Short circuit inside of the Activator or the wiring
to the Activator
•
Check if there is an short circuit form the Control Cabinet to the Activator or inside the
Activator
15.7
Communication Error
Communication Error
Connection between PLC and HMI is faulty
•
Check if the PLC is running without any fault (red LED) indication
•
Check the connection between PLC and HMI
•
Restart the PLC
Mains Switch OFF/ON