background image

 

Changing the door's left/right-handedness: 

  Open the door and push the hinge pin out of the lower hole. 

  Pull  the  pin  downwards  out  of  the  upper  hole  to  release  the  door.  Remember  the 

washers. 

  Turn the door into the desired position. 

  Slip the hinge pin first into the sleeve's upper hole and the washers on top of the sleeve 

onto the pin. (The risers on the pin must be at the lower end.) 

  Slip the door's upper hole onto the hinge pin above the sleeve. 

  Finally, guide the hinge pin into the lower holes of the sleeve and the door. 

2.8. Grate  

There is a grate in the heater's stove. Place it on brackets on the bottom of the stove. 

2.9. General directions to prevent damage 

When you bring the stove into the sauna, before you add the stones, burn a full load of wood 

in a well ventilated sauna to burn off the last protective substances and harden the 
coating. 

 
Kastor heater is ready to be used after burn-ins completed outdoors and indoors, and after 

stones have been added. 

 
 
Please read and follow the instructions below: 
 
Wood quantities can be found in table (2). 

  Remember to leave at least 10 cm of free air space as measured from the flame plate 

downwards to aid the burning process. 

  Do not heat immediately at full blast, if it is cold. The brick chimney might suffer damage. 

  Do not throw water directly at the glass door. 

  The stove’s operating life shortens, if it is constantly heated to a red glow. 

  The stove’s working life will be shortened significantly, if it is subjected to salt water. Note 

that in close proximity to the sea even well water may contain salt.The warrenty does not 
applyifthe stoveis usedsea water. 

  Factors influencing the stove’s useful life are, among other things, how well its size is 

suited to the sauna, the fuel used, how often it is used, failure to follow these instructions 
and general carefulness. 

  Kastor stoves have been very carefully designed and tested. On the basis of our studies, 

we at Helo Oy know that if the stove suffers damage in a very short time (e.g. the walls 
split or burn through, the top burns through etc.), the stove has not been used according 
to instructions. Helo Oy does not take responsibility for damage through failure to follow 
the user’s manual. 

3. Using the stove 

 

3.1. Fuel

 

Only unprocessed wood 

can be used as fuel in Kastor heaters

, preferably chopped, birch or alder 

(batch size can be seen in table (2)).

 The length of firewood is approximately 30cm. 

Dampness 12–20%. NOTE! Damp or decayed wood does not provide heat very well and 
emissions are higher.

 

 
It is not permitted to burn treated wood, wood with nails, plywood, plastic, plastic coated 

cardboard or paper in this stove. Fluid fuels must not be used even while starting the fire 

11

 

Содержание Karhu PK 007

Страница 1: ...KASTOR KARHU PK PK series wood burning sauna stoves installation and usage manual Karhu PK 007 12 16 20 27 37 18 ES 20V 27V 27ES 37V and JK models 1...

Страница 2: ...ly in KARHU models 2 5 2 KARHU JK heaters with an extended fire door 2 5 3 Installing through the wall and fitting the front frame JK models 16 20 27 37 2 5 4 Connecting from the top KARHU and KARHU J...

Страница 3: ...le material procured from reliable suppliers we have gathered over the years The steel is Finnish structural steel from Ruukki which can be bent into various solutions while retaining its hardness due...

Страница 4: ...nsported in an upright position All sticker labels and packaging material must be removed before the heater is used Type plate and the CE marking must not be removed The ash pan must be closed during...

Страница 5: ...her flammable material on the heater is forbidden due to fire risk In order to guarantee full power and safety the fire door must always be kept shut when heating The fire door can be open when heatin...

Страница 6: ...e no more fumes rising from the stove Once the stove has cooled down after the burn in move it into the sauna See to it that the sauna is well ventilated during the first couple of heating 2 1 2 SIDE...

Страница 7: ...ot give a general rule of thumb you will find the right mix by trial and error For the stove s proper functioning it is essential that the hot air circulates between the stones to heat them quickly If...

Страница 8: ...2 Reduction of safety distances Kastor protective walls and a stand are available picture 7 2 3 The chimney s isolated part must reach the protective wall Other protection is not needed If the sauna...

Страница 9: ...oor extension The fire protection measures on the door side must also adhere to the instructions in chapter 2 3 By adding fireproofing the stove and its door extension may also be installed on wooden...

Страница 10: ...a factory built Kastor chimney check 2 4 Make sure to choose the correct chimney type with regard to your stove model chimney height temperature class T 600 exterior circumstances etc For best results...

Страница 11: ...chimney might suffer damage Do not throw water directly at the glass door The stove s operating life shortens if it is constantly heated to a red glow The stove s working life will be shortened signif...

Страница 12: ...tove constantly to a red glow 3 4 Lighting Place small logs into stove parallel to the grate Amounts and total per table 2 Add kindlings under the logs and light them You can keep the fire door open f...

Страница 13: ...a fails to work as you think they should go through the following check list First to make sure you have chosen the correct stove for your sauna s requirements look through the stove choosing instruct...

Страница 14: ...connecting pipe which is red hot although the lower end of the stove within the mantle is not red See chapter 3 2 about draught adjustment and heat output Is the draught too weak See chapter 3 2 about...

Страница 15: ...is a smell of sulphur in the sauna Traces of sulphur have remained on the stones from the quarry s explosion or the stones are naturally sulphurous 6 Manufacturer s declaration www helo fi DoP This pr...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...ana Kuva 1 1 Mutteri 2 Vesis ili 3 Tiiviste 1 4 Vaippa 5 Tiiviste 2 6 Vipuhana Kran till vattenbeh llare Bild 1 1 Mutter 2 Vattenbeh llare 3 T tning 1 4 Mantel 5 T tning 2 6 Kran Water tank tap Pictur...

Страница 19: ...Aseta kivet niin ett kivien v liin j riitt v sti ilmaa Placering av bastustenarna genomsk rningbild av ugnens stenmagasin Placera bastustenarna p plats s att det blir tillr ckligt med luft mellan ste...

Страница 20: ...the Kastor protective stove base Kastor Kastor A Karhu 007 PK 105mm Karhu 12 PK 110mm Karhu 16 PK 120mm Karhu 20 PK 120mm Karhu 27 PK 125mm Karhu 37 PK 125mm Kuva bild picture p 2 3 Kastor kiukaan ase...

Страница 21: ...tenen Anslutning av ugnen ovanifr n till Connecting the stove from the back to a brick chimney tegelskorstenen Connecting the stove from the top to a brick chimney Kuva bild picture p 2 6 Liitt minen...

Страница 22: ...1 Savupeltilaite R kspj ll Chimney valve device 22...

Страница 23: ...fr n ugnen A Det oisolerade f rbindelser ret uppifr n n r det kopplas till br nnbart material fr n f rbindelser rets yta till sidan 400mm upp t 400mm B Ugnens avst nd fr n br nnbart material till sid...

Страница 24: ...A 400 400 B 500 C 50 D 500 E 50 F 400 Kuva bild picture p 6 Kuva bild picture p 7 24...

Страница 25: ...25...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...28...

Страница 29: ...29...

Страница 30: ...30...

Страница 31: ...31...

Страница 32: ...32...

Страница 33: ...v 4 05 11 13 33...

Отзывы: