manualshive.com logo in svg
background image

LED4C11 MANUAL

8

• 

C-25 control panel: The C-25 timer must be turned on (fountain operating) to allow the light circuit to 

energize. 

• 

C-85, or C-95 control panel with GFCI outlet and photo eye control: The fountain timer must be 

turned on (fountain operating) to allow the light circuit to energize. While the photo eye is covered, 

the GFCI outlet can be reset if tripped.

The timer may not be set properly.

• 

C-85, or C-95 control panel (and all 3phase fountain control panels) with terminal connections and 

timer control for light kit: The control panel has a second timer for controlling the lights (no photo eye). 

Ensure the light timer is set to operate the lights. The timer has a built-in Hand-Off-Auto switch. Ensure 

the switch is set properly. Ensure the fountain is turned on. The light timer will not energize the light kit 

unless the fountain circuit is energized.

The GFCI may be tripped.

•  C-25 control panel: Reset the GFCI. If the GFCI does not reset it could be a ground fault in the fountain 

wiring, or the light kit wiring. Unplug both the fountain and light kit and reset the GFCI. If it resets, plug 

fountain then light kit back in and see which one trips the GFCI. If the GFCI does not reset with both un-

plugged, then the GFCI may be defective.

• 

C-85, or C-95 control panel with GFCI outlet and photo eye control: To reset the GFCI outlet the fountain 

timer must be turned on, and the photo eye must be activated. (Black electrical tape can be wrapped 

around the photo eye to activate it.) Once these are on, the GFCI reset button can be pressed. (Unplug 

the light kit prior.) Plug the light kit in and see if it operates. If the GFCI trips again then the light kit may 

be damaged. If the GFCI does not reset (with light kit unplugged) then it may be defective, or the photo 

eye is not activated to send power to the outlet.

• 

C-85, or C-95 control panel with terminal connections and timer control for light kit: For panels with a 

GFCB (ground fault circuit breaker) and timer-controlled lights, simply reset the two-pole breaker. This 

will turn the fountain and light kit back on if the timers are set to on. If it trips again, disconnect the light 

kit from the terminals and reset. 

WARNING! 

You must turn off power to the panel before disconnecting 

any wiring from the terminals. If the breaker trips with the light kit disconnected, then disconnect the 

fountain as well and reset. If the breaker continues to trip it may be a defective GFCB. If the breaker 

resets, then reconnect the fountain then the light kit to see which one trips the GFCB.

• 

3phase fountain control panels: 3phase fountain panels have a ground fault sensing module that will 

trip if either the light kit or fountain has a ground fault. To reset the module, simply press the reset 

button in the panel. This will turn the fountain and light kit back on if the timers are set to on. If it trips 

again, disconnect the light kit from the terminals and reset. 

WARNING!

 You must turn off power to the 

panel before disconnecting any wiring from the terminals. If the GFI module trips with the light kit dis-

connected, then disconnect the fountain as well and reset. If the GFI module continues to trip it may be 

a defective module or an internal wiring issue with the panel. If the module resets, then reconnect the 

fountain then the light kit to see which one trips the module.

“My lights work, but they are not as bright as they were when first installed.”

Dirty lenses may be to blame.

• 

Turn off power to the control panel and disconnect power cords to the fountain and the light kit. Bring 

the fountain to the shore and inspect the light kit lenses. Over time, algae growth and hard water depos-

its on the lenses can block light output. Clean the lenses with a soft brush and the light should be bright 

again.

TROUBLESHOOTING TIPS (CONT.)

Back to Contents

Содержание WaterGlow LED4C11

Страница 1: ...Rd Prescott WI 54021 715 262 4488 sales kascomarine com kascomarine com MOVING WATER FORWARD SINCE 1968 LED4C11 Operation Maintenance Manual Document number 884014 Document version 2021 2 0 Universal Composite WaterGlow Lighting ...

Страница 2: ...e com sales kascomarine com TABLE OF CONTENTS QUESTIONS Safety First 2 Parts Included 3 Universal Mounting Instructions 4 Maintenance Recommendations 7 Troubleshooting Tips 7 Warranty 9 Repair 9 Non Warranty Repairs 10 Repair Contact Form 11 ...

Страница 3: ...d in and of itself NEVER lift or drag the equipment by the power cords If you need to pull the unit to the side of the pond use the anchoring ropes Do not use boats that tip easily for lighting kit installation and follow all boating safety rules and regu lations including wearing a PFD Personal Flotation Device Do not use waders in deep ponds lakes or ponds lakes with drop offs drastic slopes or ...

Страница 4: ...3 F 10 split lock washer 8 771037 G Bracket O ring 8 345008 H Composite light bracket 4 345007 I 10 32 x 1 2 hex screw 8 345042 J 1 4 20 x 1 3 8 hex screw 4 584692 K 1 4 5 8 O D flat washer 4 258476 L 1 4 20 split lock washer 12 840537 M 1 4 20 nut 8 840536 N Cable tie not shown 8 415038 Universal Mounting Hardware O Universal mounting bracket 4 345060 P 1 4 20 x 3 4 hex screw 4 840539 Q 1 4 fende...

Страница 5: ...cket works better in a horizontal or vertical configuration for your application see page 6 before attaching the composite light bracket to the fixture Some config urations require the composite light bracket to be flipped from what is pictured here 2 Optional If you want to use one of the color choices instead of the standard soft white light peel the protective lining from both sides of the colo...

Страница 6: ...he cap is seated all the way down onto the fixture housing as shown Make sure the fixture and lens are clean before installing the lens cap Repeat for all fixtures 4 Assemble parts J K L and M as shown to secure the fixture to the float and tighten until secure 7 16 socket and wrench required A B C J L M K Back to Contents ...

Страница 7: ... H to the Universal mounting brackets O Use 1 4 20 x 3 4 hex screws R fender wash ers Q lock washers L and hex nut M to secure the Universal bracket to the float Composite light bracket H needs to be flipped upside down for horizontal mounting 6 Repeat for remaining fixtures spacing evenly around the float Adjust the angle of the lights using thumb nuts if desired being sure to use the same angle ...

Страница 8: ...rom the expansion pressure of ice Storage over winter is best in a location that is out of the sun and cool but above 32 F Cleaning Light kits should be removed from the water at least once per year at the end of the season in cold climates to clean the exterior of the system The light fixture surfaces dissipate heat into the water and any algae calcium or other build up will become an insulator t...

Страница 9: ...wer to the outlet C 85 or C 95 control panel with terminal connections and timer control for light kit For panels with a GFCB ground fault circuit breaker and timer controlled lights simply reset the two pole breaker This will turn the fountain and light kit back on if the timers are set to on If it trips again disconnect the light kit from the terminals and reset WARNING You must turn off power t...

Страница 10: ...receipt and registering the equipment online at kascomarine com under the Warranty Information section Once warranty coverage has been established the light kit may be sent to Kasco or any Kasco Authorized Repair Center for evaluation and repair The LED light fixtures are sealed and do not require any physical maintenance other than cleaning Any required repairs must be performed by Kasco Any alte...

Страница 11: ...the work is performed All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer Rejected equipment can be returned at the customer s expense for shipping and handling charges Billing All non warranty repairs will be returned and billed to the customer unless otherwise directed Kasco accepts Visa and MasterCard credit card payments Kasco will call for cr...

Страница 12: ...chemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention Unit should be cleaned before shipping Kasco is NOT responsible for shipping damage accrued in return shipment It is the responsibility of the cus...

Отзывы: