manualshive.com logo in svg
background image

LED3S19, LED6S19 WATERGLOW STAINLESS STEEL LIGHTING

MANUAL

884050 / 2021.1.2

9

TROUBLESHOOTING TIPS

TROUBLESHOOTING TIPS

The following is provided to help diagnose a probable source of trouble. It is a guideline only and may not show all causes for all problems. For 

additional troubleshooting help, contact your local distributor or visit 

kascomarine�com

 for additional guidance. Note: you may need to refer to your 

owner’s manual that was provided with your fountain for additional control panel settings and adjustments.

“My light kit is installed and wired but will not turn on.”

Ensure control panel is connected to the electrical circuit. Verify circuit breakers, timers, and/or interlock switches are turned on and functional. Refer 

to your owner’s manual that was provided with the fountain.

It may not be dark enough for the photo eye on the control panel to activate.

• 

Kasco C-25, C-85, and C-95 control panels have a photo eye on the left side of the enclosure exterior. This photo eye measures ambient light. 

To activate, the photo eye must not measure any ambient light for at least several minutes. Covering the photo eye with black electrical tape will 

activate the photo eye for testing.

• 

C-25 control panel: The C-25 timer must be turned on (fountain operating) to allow the light circuit to energize. 

• 

C-85, or C-95 control panel with GFCI outlet and photo eye control: The fountain timer must be turned on (fountain operating) to allow the 

light circuit to energize. While the photo eye is covered, the GFCI outlet can be reset if tripped.

The timer may not be set properly�

• 

C-85, or C-95 control panel (and all 3phase fountain control panels) with terminal connections and timer control for light kit: The control panel 

has a second timer for controlling the lights (no photo eye). Ensure the light timer is set to operate the lights. The timer has a built-in Hand-Off-

Auto switch. Ensure the switch is set properly. Ensure the fountain is turned on. The light timer will not energize the light kit unless the fountain 

circuit is energized.

The GFCI may be tripped�

• 

C-25 control panel: Reset the GFCI. If the GFCI does not reset it could be a ground fault in the fountain wiring, or the light kit wiring. Unplug 

both the fountain and light kit and reset the GFCI. If it resets, plug fountain then light kit back in and see which one trips the GFCI. If the GFCI 

does not reset with both unplugged, then the GFCI may be defective.

• 

C-85, or C-95 control panel with GFCI outlet and photo eye control: To reset the GFCI outlet the fountain timer must be turned on, and the photo 

eye must be activated. (Black electrical tape can be wrapped around the photo eye to activate it.) Once these are on, the GFCI reset button can 

be pressed. (Unplug the light kit prior.) Plug the light kit in and see if it operates. If the GFCI trips again then the light kit may be damaged. If the 

GFCI does not reset (with light kit unplugged) then it may be defective, or the photo eye is not activated to send power to the outlet.

• 

C-85, or C-95 control panel with terminal connections and timer control for light kit: For panels with a GFCB (ground fault circuit breaker) and 

timer-controlled lights, simply reset the two-pole breaker. This will turn the fountain and light kit back on if the timers are set to on. If it trips 

again, disconnect the light kit from the terminals and reset. 

WARNING!

 You must turn off power to the panel before disconnecting any wiring 

from the terminals. If the breaker trips with the light kit disconnected, then disconnect the fountain as well and reset. If the breaker continues to 

trip it may be a defective GFCB. If the breaker resets, then reconnect the fountain then the light kit to see which one trips the GFCB.

• 

3phase fountain control panels: 3phase fountain panels have a ground fault sensing module that will trip if either the light kit or fountain has a 

ground fault. To reset the module, simply press the reset button in the panel. This will turn the fountain and light kit back on if the timers are set 

to on. If it trips again, disconnect the light kit from the terminals and reset. 

WARNING! 

You must turn off power to the panel before disconnect

-

ing any wiring from the terminals. If the GFI module trips with the light kit disconnected, then disconnect the fountain as well and reset. If the 

GFI module continues to trip it may be a defective module or an internal wiring issue with the panel. If the module resets, then reconnect the 

fountain then the light kit to see which one trips the module�

“My lights work, but they are not as bright as they were when first installed.”

Dirty lenses may be to blame�

•  Turn off power to the control panel and disconnect power cords to the fountain and the light kit� Bring the fountain to the shore and inspect the 

light kit lenses. Over time, algae growth and hard water deposits on the lenses can block light output. Clean the lenses with a soft brush and the 

light should be bright again�

Back to Contents

Содержание WaterGlow LED3S19

Страница 1: ...LED3S19 LED6S19 WaterGlow Stainless Steel Lighting Operation Maintenance Manual 800 Deere Rd Prescott WI 54021 715 262 4488 sales kascomarine com www kascomarine com Document number 884050...

Страница 2: ...GFCI receptacle They are intended to be mounted on a floating fountain or aerator for use in a natural or man made body of water to comply with NEC Article 682 Kasco WaterGlow lighting kits have not b...

Страница 3: ...le quantities for 6 light kit ID Description Quantity Part A Lens cap S19 3 346090 B Colored lens kit 4 colros 1 345559 C LEDS19 fixture 3 LEDS19 D 1 4 20 x 1 2 hex screw 6 451126 E 1 4 lock washer 6...

Страница 4: ...washers E 7 16 wrench required Repeat this step for all fixtures 2 Optional If you want to use one of the color choices instead of the standard soft white light unpeel the protective lining from both...

Страница 5: ...re C as shown Ensure the cap is seated all the way down onto the fixture housing Make sure the fixture and lens are clean before installing the lens cap Repeat for all fixtures 4 Slide bracket into th...

Страница 6: ...desired being sure to use the same angle for all fixtures Cable ties can be used to attach fixture cords to float to decrease play and ensure protection Cable tie O the light kit power cord to the fl...

Страница 7: ...light fixtures on aerating fountain units with the mounting brackets oriented as shown will ensure proper submersion of the light fixtures Each fixture must be partially submerged in order for lights...

Страница 8: ...Repair Center or to Kasco at NON WARRANTY REPAIRS NON WARRANTY REPAIRS Most failed equipment can be repaired at substantially lower costs than replacement with new If your light kit requires repair a...

Страница 9: ...th both unplugged then the GFCI may be defective C 85 or C 95 control panel with GFCI outlet and photo eye control To reset the GFCI outlet the fountain timer must be turned on and the photo eye must...

Страница 10: ...LED3S19 LED6S19 WATERGLOW STAINLESS STEEL LIGHTING MANUAL 884050 2021 1 2 10 Back to Contents...

Страница 11: ...ty of the customer to ship and pay freight to Kasco Note Contact Information should be that of the person or company to contact for repair information Company name Contact name First name Last name Ad...

Отзывы: