LED3S19, LED6S19 WATERGLOW STAINLESS STEEL LIGHTING
MANUAL
884050 / 2021.1.2
6
5�
After attaching the unit to the float according to fountain/aerator instructions, push the clips into recesses on float until you hear an
audible click indicating the fixture is secure.
Ensure clip is
fully seated on float
6. Repeat for remaining fixtures, spacing evenly around the float. Adjust the angle of the lights if desired, being sure to use the same
angle for all fixtures. Cable ties can be used to attach fixture cords to float to decrease play and ensure protection. Cable-tie (O)
the light kit power cord to the float opposite the fountain power cord for balance and to prevent damage from the fountain. Upon
installation of the assembled unit, connect the light kit to a field-installed GFCI protected outlet and timer. Remember: LEDS19
fixtures MUST be properly submerged (to mark on housing) to avoid overheating
Secure light kit power
cord to float using
suppiled cable ties.
Fig. 10
Fig. 11
Fig. 12
Back to Contents