3-PHASE STARTUP PROCEDURE

Required motor starting/overload protection is not provided with this motor equipment.  The installer must 

supply a controller (control panel) with approved motor control and overload protection that matches motor 

input Full load amperes. (See table below.) Overload protection must be selected or adjusted in accordance 

with motor controller instructions.
Controller/control panel must also include Ground fault/leakage current protection. Installer must include 

Ground fault/leakage current protection such as a GFI, RCD, RCBB, RCBO according to local and national 

codes.  

Control panels must be installed by a qualified electrician. 

If unit is connected to a circuit protected by a fuse, use a time-delay fuse with this pump. 

You must verify motor rotation before installing the unit in the water. 

3-phase Kasco units will run in a 

clockwise rotation when looking down at the propeller. Keep clear of the propeller while verifying rotation. 

Air will be blowing out (up) of the pump chamber when rotating in the correct direction.

Electrician: 

1. 

Verify all screw terminal connections are tightened to specified torque setting prior to energizing the 

panel. 

2.  Verify the electrical service (voltage and phase) matches the control panel and fountain nameplate 

ratings. 

3.  Verify all switches, circuit breakers, and motor starters are in the OFF position
4.  Connect electrical service to the control panel.
5.  Connect the fountain power cord to the panel as shown in the electrical schematic. 
6.  Adjust motor overload protection according to motor full load amperage and motor controller 

instructions.

7.  Pump rotation: The pump rotation is clockwise when looking down at the propeller. Apply power to the 

control panel. Turn on the motor starter.

8.  Momentarily turn on the fountain. Do not run the fountain for more than a few seconds on shore. If 

the rotation is not correct, disconnect and lock out power from the control panel. Swap any two of the 

fountain power cord wires in the panel. This will cause the motor to reverse direction. Reapply power to 

the panel and verify the rotation is clockwise. 

9. 

Once rotation is verified, with the power disconnected and locked out again, continue with installation of 

the fountain on page 9.

Record the following data while the unit is operating in the water under load:

L1-L2 

  Volts 

 

 L1 

  Amps

L1-L3 

  Volts 

 

 L2 

  Amps

L2-L3 

  Volts 

 L3 

  Amps

Current unbalance should not exceed 5% at full load.

3-phase 380V

5.3EHJF

Full load amps

7.7

Содержание 5.3EHJ

Страница 1: ...UNTAIN MANUAL 1 MOVING WATER FORWARD SINCE 1968 Operation Maintenance Manual Document number 884157 Document version 2022 1 0 EJ SERIES FOUNTAIN 5 3EHJ 800 Deere Rd Prescott WI 54021 sales kascomarine com kascomarine com ...

Страница 2: ...ncluded 5 Installation Instructions 9 Maintenance Recommendations 11 Troubleshooting Tips 12 Warranty 13 Other Repairs 14 Repair Contact Form 15 OVERVIEW Model HP Voltage Phase Hz Amperage Locked Rotor Amps Suggested Pond Size m Min Depth of Operation 5 3EHJF 5 380 3 50 7 7 27 10 000 71cm UNIT SPECIFICATIONS Wire size for all cord lenths is 2 5mm ...

Страница 3: ...nd national codes Stay clear of all moving parts NEVER run the unit out of water This will damage the equipment and pose a danger to the operator Use extreme caution around water especially cold water NEVER lift or drag the unit by the power cord Always use the ropes or mount to remove it from the water Do not use waders in deep water or in areas with drop offs drastic slopes or soft bottom materi...

Страница 4: ...on F Nozzle O ring Large J 1 841217 G Large JF unit assembly 1 See Table below H Bottom screen large aerator 1 990162 I Bottom screen clip large aerator 3 223240 J 3 8 16 x 1 2 serrated hex head screw 3 820092 K 7 16 9 16 wrench tool 1 284139 L 1 4 mesh screen not pictured 1 990175 M 3 4 mesh screen not pictured 1 990170 N Rope 50ft not pictured 1 990170 O Cable tie not pictured 8 415038 P Dielect...

Страница 5: ...Outlet Balsam 841273 HP Height Width 5 4 7m 9 4m Spruce 841242 HP Height Width 5 7 9m 2 7m HP Height Width 5 5 8m 3m Birch 841222 Redwood 841250 HP Height Width 5 8 1m 1 8m 841242 Spruce 841250 The outlet nozzle 841222 comes installed Add the parts listed below for Linden and Balsam patterns remove it before installing Birch Spruce or Redwood nozzles ...

Страница 6: ...com or your local distributor for order information Madrone 841330 Magnolia 841325 Palm 841320 Mahogany 841345 Mighty Oak 841335 841250 841250 841250 841250 841250 HP Height Width 5 7m 18 9m HP Height Width 5 6 2m 22 6m HP Height Width 5 5 1m 10 4m HP Height Width 5 6 9m 18 9m HP Height Width 5 6 9m 18 3m ...

Страница 7: ...LARGE EJ SERIES FOUNTAIN MANUAL 6 ASSEMBLY INSTRUCTIONS Dedicated power cord channel D G A B C 1 2 3 Repeat I J 4 ...

Страница 8: ...BLY INSTRUCTIONS CONT 5 6 7 8 Use cable ties to secure close mesh screen and then to secure it to the metal bottom screen H Dedicated power cord channel 9 Tighten all 3 screws to secure float screen Vertical bar in between clip flanges 10 11 ...

Страница 9: ...LARGE EJ SERIES FOUNTAIN MANUAL 8 NOZZLE INSTALLATION INSTRUCTIONS Twist until snug For Linden Balsam Nozzles OUTLET 6 nozzle installed Balsam Linden F E 1 2 3 Do not over tighten 1 2 ...

Страница 10: ... rope Secondary weight Normal water level Low water level High water level Alternate Installation Correct anchoring Incorrect anchoring Mooring lines are proper length and taut between unit and anchors at least 3 feet from the float for every foot of water depth Mooring lines are too short or loose between unit and anchors ...

Страница 11: ...to specified torque setting prior to energizing the panel 2 Verify the electrical service voltage and phase matches the control panel and fountain nameplate ratings 3 Verify all switches circuit breakers and motor starters are in the OFF position 4 Connect electrical service to the control panel 5 Connect the fountain power cord to the panel as shown in the electrical schematic 6 Adjust motor over...

Страница 12: ...is inspect and clean the equipment regularly In all regions inspect and clean the equipment at least once a year It is easiest to clean the unit immediately after removing it from the water when the equipment is still wet If you use a power washer avoid hitting the mechanical seal area directly Unit Storage Store the equipment with the cage down if it is going to be out of the water for long perio...

Страница 13: ...s and will not start Typically indicates a motor capacitor problem single phase motor a motor controller problem 3 phase or debris preventing the unit from starting Turn the unit off and disconnect from power source to prevent motor damage Remove the equipment from the water and inspect for debris or damage Remove the debris and clean the equipment If there is no debris in the unit and it will not...

Страница 14: ... Once the warranty coverage has been established the unit may be sent to any Kasco authorized repair center for evaluation and repair Please call Kasco at 715 262 4488 prior to shipping to receive any updated information or a repair form or call to locate your nearest authorized repair center You can also email Kasco at sales kascomarine com Please include the repair form received from Kasco or yo...

Страница 15: ...st for repairs after we have evaluated the unit but before we perform the work We will repair the unit only if repair costs are under a dollar amount stated by the customer Example Please repair if total is under 150 00 before shipping charges All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer If the customer would like the unit returned we will ...

Страница 16: ...cian Was this unit used in a chemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention Unit should be cleaned before shipping Kasco is NOT responsible for shipping damage accrued in return shipment It is ...

Отзывы: