b.4 Installing the flue gas outlet
The installation can be performed either without a masonry flue, or with an existing flue.
FIG 1. INSTALLATION WITHOUT A MASONRY FLUE
Flue gas outlet Ø 100 – Using an easy to inspect T-joint, reach the outside of the building
horizontally; proceed vertically until you reach the roof with a cohibented flue, equipped with an
anti-wind chimneystack. All the joints must be sealed.
FIG. 2. INSTALLATION WITH AN EXISTING FLUE
Flue gas outlet Ø 100 – Reach the existing flue horizontally, making sure that it presents a
minimum section of 200cm² and an easy to inspect base, for its annual cleaning. All the joints must
be sealed.
IMPORTANT!! We recommend you to have the installing technician verify the efficiency and the
state of the flue, the observance of national and local laws regarding flue gas outlets’ joints, and to
use appropriate materials.
The information reported above is purely indicative for a correct installation; Karmek Srl is not
responsible for what concerns the installation.