• 17 •
1 Installing control unit
Figure
1 4
The control unit is installed at an approx. height of 1.70
metres, next to the cabin door or in accordance with
the cabin manufacturer’s recommendations.
The network cable contained in the scope of supply
must be used to provide the electrical supply.
CAUTION – Damage to the device:
The control unit is protected from spray water
(protection class IP X4). However, the control unit
should not come into direct contact with water.
Install the control unit in a dry place. Do not ex-
ceed ambient conditions of 40°C and maximum air
humidity of 95 per cent.
1. Insert the cross head screw at a height of approx.
1.80 metres up to a distance of 7 mm from the sauna
wall (see detail).
2. Suspend lower section of housing
1
in position
2
onto the mounted cross head screw.
CAUTION – Damage to the device:
The Modern Bio Plug‘n‘Play control unit must only
be used to control and regulate 1 heating circuit
with a maximum heating power of 3.6 kW. The
heater sensors and bench sensor cables must be
installed separately to other network cables in the
low voltage connection range of the control unit.
3. Guide heater sensor cables through the installation
openings
4
into the lower section of the housing
1
and plug in.
4. Guide bench sensor cables through the installation
openings
4
into the lower section of the housing
1
and plug in.
5. Guide supply cable
6
, heating system cable
5
and light cable
7
through the respective installation
openings into the lower section of the housing
1
and plug in.
6. Insert two cross head screws, 60mm in length, into
the lower anchor points
9
and bolt the wood co-
vering
8
flush with the lower section of the housing
1
. Verify the secure fit of the lower section of the
housing
1
.
Installation instructions
1 continued Figure
1 4
CAUTION:
The plugs for the supply, heating system and light
cables are coded and can thus only be plugged in
using the correct connection sequence.
Содержание Modern Bio Plug'n'Play
Страница 12: ...12 Anschlussplan Sauna und Verdampfer Steuerung Modern Bio Plug n Play Abbildung 1 Abbildung 2 Abbildung 3...
Страница 13: ...13 Abbildung 4 Abbildung 5...
Страница 14: ...Notizen...
Страница 26: ...26 Connection diagram Modern Bio Plug n Play sauna and evaporator control unit Figure 1 Figure 2 Figure 3...
Страница 27: ...27 Figure 4 Figure 5...
Страница 28: ...28 Notes...
Страница 41: ...41 Illustration 4 Illustration 5...
Страница 42: ...Notes...
Страница 55: ...55 Figura 4 Figura 5...
Страница 56: ...56 Appunti...
Страница 68: ...68 Aansluitingsschema Sauna en stomerbediening Modern Bio Plug n Play Afbeelding 1 Afbeelding 2 Afbeelding 3...
Страница 69: ...69 Afbeelding 4 Afbeelding 5...
Страница 70: ...Notities...
Страница 71: ...Notities...
Страница 72: ...Notities...