Chapter 3 Operation Panel
25
Code
Parameter
Function
Explanation
Parameter Value
Factory
Setting
Pr.063
PWM
Frequency
setting
d0000
:
FPWM=2.9KHz,
d0001
:
FPWM=5.8KHz
d0000
Pr.064
Auto
reset
after fault
d0000—d0010
d0000
Pr.065
First
fault
record
d0000: Fault records clear (No errors
occurred )
d0000
d0001: Over-current (oc)
d0002: Over-voltage (ov)
d0003: Overheat (oH)
d0004: Overload (oL)
d0005: Overload 1 (oL1)
d0006: External fault (EF)
d0007: CPU failure 1 (CF1)
d0008: CPU Failure 3 (CF3)
d0009: Hardware protection failure (HPF)
d0010: O.C. during acceleration (ocA)
d0011: O.C. during deceleration (ocd)
d0012: O.C. during steady state operation
(ocn)
d0013: Ground fault or fuse failure (GFF)
d0014-16: Reserved for manufacture
diagnosis
d0017: External base block (bb)
d0018: Overload 2 (oL2)
d0019-20: Reserved for manufacture
diagnosis
Содержание KD4000-2S Series
Страница 5: ...Chapter 2 Installation and wiring 4 2 2 KD4000 4T 380V Series Installation Dimension...
Страница 6: ...Chapter 2 Installation and wiring 5 2 3 KD4000 2S 220V basic wiring diagram...
Страница 7: ...Chapter 2 Installation and wiring 6 2 4 SD4000 4T 380V basic wiring diagram...
Страница 15: ...Chapter 3 Operation Panel 14 3 3 Please observe below steps to set parameters...