30
Maintenance schedule
Time
Activity
Assembly affectedPerformance
By whom
once a year
before the
frosting peri-
od starts
Clean the filter
Antifreezing circula-
tion
Empty and clean the collection chute for the frost protection water.
Clean the filter on the immersion pump.
Clean the filter of the frost protection pump (in the casing of the SB
MB).
Clean the tool compartment and check for free flow.
Clean the throttle valve (in the area of the high pressure pump outlet).
Fill the collection chute for the frost protection water with fresh water.
Operator/
Customer
Service
opinion
Washing station
heater
Check functioning and rotation direction of the circulation pump
Check concentration of anti-freezing agent: Take out a little anti-freez-
ing solution from the safety valve and check its correct concentration
using a special tester (6.419-070.0). Target value -25°C
Check pressure in the heating circuit. Nominal value with running cir-
culation pump of the washing station heater 0.07...0.15 MPa (0.7...1.5
bar)
Check setting of the thermostat mixing valve.
Check the function of the balancing vessel: Remove the valve flap.
Press in the valve pin briefly using a matchstick. The balancing vehicle
is OK if air comes out. If water comes out, then the balancing vessel
needs to be replaced. If nothing comes out, then use a car air pump to
pump in air in the balancing vehicle according to the values on the type
plate.
opinion
External thermostat Check function.
Operator
opinion
Recirculation blow-
er
Check function.
Operator
opinion
Hot blowers
Have the regulators been set correctly? (See section "Settings/hot air
ventilator".)
Operator
opinion
Frost protection
with lost water
Switch on the frost protection pump (see Chapter "Manual procedures").
Check if at least 0.5 l/min of water exits each hand spray gun, if neces-
sary, readjust the pressure reducer.
Operator
opinion
Emergency frost
protection
Turn the main switch to position “0”.
Check if at least 0.5 l/min of water exits each hand spray gun, if neces-
sary, readjust the pressure reducer.
Operator
Clean the filter
Pass boiler
Recommendation: These half-yearly maintenance tasks are to be done
before the frosting period starts.
Customer
Service
measuring
Burner
daily
opinion
High pressure hos-
es, foam hoses
(with 2 tool model)
Check high pressure hoses for mechanical damages such as scraping,
visible hose duck, bends, porous and cracked rubber. Replace dam-
aged high pressure hoses.
Operator
opinion
Information signs at
the washdown yard
Check whether the warning boards for the users are available and leg-
ible.
Operator
opinion
Washing station
lighting
Check the function of the washing station lighting and replace defective
lights.
Operator
opinion
Spray lance
Check for tightness; replace O-ring if necessary. Nozzle protection and
handle pipe OK? Replace if necessary.
Operator
opinion
Hand spray gun
Check for tightness; replace O-ring if necessary.
Operator
Can the high-pressure hose be rotated, and is the lever running
smoothly? Lubricate if nessary (see section „Maintenance work“).
opinion
Tool storage box
Check from the outside for foreing matters and contamination. Remove
coarse contaminants.
Operator
opinion
Fill levels of the de-
tergent container
Check filling level, refill or replace if necessary.
Operator
empty
Coins container
Open the coin acceptor doors and empty the coin container.
Operator
Initially dai-
ly, later on
based on ex-
perience
opinion
Filling level of the
fuel tank
Will the heating oil be sufficient till next inspection? Take into account
increased consumption due to anti-frost equipment. Insufficient fuel
can lead to failure and damage to the system.
Operator
empty
Compressor
Drain the condensate from the pressure container of the compressor. Operator
Everyday
under frost
conditions
opinion
Anti frost devices Are the hot air ventilators working (even for ABS fuel tank, option)? Operator
Clean the filter
Filter for frost-pro-
tection pump
Clean the filter and replace
Operator
32
EN
Содержание SB MB
Страница 1: ...SB MB 59638780 04 17...
Страница 2: ...2...
Страница 10: ...8 1 Menu item 2 Parameter 10 EN...
Страница 29: ...27 29 EN...
Страница 50: ...48 SB MB standard SB MB comfort Dimension drawing for CAB model 50 EN...
Страница 51: ...49 SB MB standard SB MB comfort Dimension drawing for SKID model 51 EN...
Страница 52: ...50 Dimension drawing for SKID model with WSO upgrade kit 52 EN...