13
Note:
The pre-requisites for frost protection are:
– The main switch must be in position 1.
– The doors of the system must be
closed.
– Uninterrupted power, water and fuel
supply must be ensured.
– Water supply must also be protected
against freezing.
– The fuel supply must be protected
against frost (e.g. heating cartridge in
the tank, trace heating),
– Instructions for assembling and installa-
tion are given in chapter "Installing the
plant".
– The hot air ventilators have been set
correctly.
– All maintenance steps according to
"Maintenance and Care" have been
carried out correctly.
– All cleaning tools are placed back in the
storage compartment.
– The trigger guns with frost protection
holes that are part of the system are in-
stalled.
Note:
The washing place heating can function
properly provided the washing area has
been built properly according to the
KÄRCHER recommendations.
The heating power is sufficient for a heated
washing station surface of 50/60* m
2
. If the
heated surface exceeds this value, the frost
protection cannot be guaranteed.
Snow layers and large volumes of ice piec-
es fallen from the vehicles require a very
high heating capacity. It is necessary to re-
move these deposits.
* 50 m
2
with gas burner (64 kW); 60 m
2
with
oil burner (72 kW); with 4 high-pressure
modules type 908 the washing station sur-
face must be further reduced.
Before the onset of the frost period,
maintenance tasks must be carried out
"every year before the onset of the forst
period" according to section "Mainte-
nance and Care".
Carry out the following tasks for keep-
ing the frost protection intact.
Note:
Maintenance not being done on time or
from experts will mean, that there is no
guarantee concerning frost damage.
1 Locking valve
1 Throttle with sieve (marked red), 1-tool-
model
1 Filter for frost-protection pump
Washing station heater
Maintenance jobs before and during
the frost period
Time
Activity
Assembly affected
Performance
By whom
many times
daily
opinion
Washing brush
Check for dirt and ice formation; lock foam wash if needed.
Operator
daily
Clean the
filter
Filter for frost-protection
pump
Clean the filter and replace
Operator
opinion
Hot blowers
Are the hot air ventilators working (even for ABS fuel tank, option)? Operator
Recirculation blower
Check function.
Operator
Initially daily,
later on based
on experience
opinion
Filling level of the fuel tank Will the heating oil be sufficient till next inspection? Take into ac-
count increased consumption due to anti-frost equipment. Insuffi-
cient fuel can lead to failure and damage to the system.
Operator
weekly
opinion
Heating ABS heating oil
tank (option)
With temperatures below 3°C, check if the trace heating of the heat-
ing oil line between the heating oil tank and SB MB is warm.
Operator
monthly or af-
ter 200 oper-
ating hours;
more fre-
quently if
needed
opinion
Quantity of frost water pro-
tection in the frost protec-
tion circuit
Target value: approx. 0.5 l/min per washing tool
Water quantity is higher: Change the node piece in the hand-spray
gun.
몇
WARNING
Risk of injury and damage. If the frost protection water volume is big-
ger than the admissible value, the cleaning tool may move uncon-
trollably due to the exiting water stream. If the frost protection water
volume is too big, replace the union piece in the trigger gun by all
means.
Water quantity is lesser Clean filter for frost protection pump; clean
sieve in throttle, clean pipes, check the rotation direction of the
pump.
Operator
15
EN
Содержание SB MB
Страница 1: ...SB MB 59638780 04 17...
Страница 2: ...2...
Страница 10: ...8 1 Menu item 2 Parameter 10 EN...
Страница 29: ...27 29 EN...
Страница 50: ...48 SB MB standard SB MB comfort Dimension drawing for CAB model 50 EN...
Страница 51: ...49 SB MB standard SB MB comfort Dimension drawing for SKID model 51 EN...
Страница 52: ...50 Dimension drawing for SKID model with WSO upgrade kit 52 EN...