Troubleshooting and fault elimination
23/49
Troubleshooting and fault elimination
Safety instructions
WARNING
Before starting work
remove the plug from the wall socket!
Before work for troubleshooting is started, the parking brakes at the undercarriage must be activated.
If harmful substances escape due to a defect (eg filter defect), the machinery must be switched off
immediately and the room has to be aired or leave!
• Before starting any work on the industrial vacuum cleaner, but particularly before opening covers of
live or moving parts, the industrial vacuum cleaner or system must be correctly disconnected from
the mains and the drive unit must have stopped
• The measures specified below may only be withdrawn when the industrial vacuum cleaner is
completely reassembled and the maintenance is concluded.
•
The usual
safety regulations
are, for example, in accordance with
VDE 0105
:
– Disconnect from mains
– Provide a safeguard to prevent unintentional restarting
– Check that the equipment is not live
– Cover or shield adjacent live parts.
Initial fault elimination measures
könne
All the errors mentioned in the table below may be eliminated by yourself. In case of major problems
or other failures please contact the customer service of Ringler immediately.
Tel. ++49-(0)7171-94888-0
Perform maintenance tasks in accordance with the description in the Maintenance/Servicing chapter
Interference
Possible cause
Remedy
Reduced
suction
power
Extraction hose or nozzle clogged
Extraction hose leaking
Extraction hose not fitted correctly in extraction
socket
Collection container full
Area filter/pocket filter contaminated
Seal between drive unit and collection container
defective
Extraction turbine defective
Remove clogging
Replace hose
Insert hose correctly
Empty collective container
Clean or replace filter
Clean or replace seal
Replace suction turbine by
electrician
Device not
running
Rotary field monitoring reports motor was turning
in the wrong direction
Inspection by electrician/phase
run
Extraction
motor is not
running
correctly
2 phase run
Motor protection switch has triggered
Fuse triggered
Inspection by electrician
Fuses trigger
Fuse too low
Defective switch
Defective motor
Inspection by electrician
Motor runs
too hot
Cooling air volume too low, cooling air paths
clogged
Ensure uninhibited supply and
exit of cooling air
Содержание ID 30/30 Afc
Страница 1: ...Translation of the Original Operating Manual ID 30 30 Afc ID 50 40 Afc...
Страница 2: ...2 49...
Страница 6: ...Delivery internal transportation unpacking 6 49...
Страница 37: ...Spare Parts List 37 49 Drive Part IE2 for control...
Страница 38: ...Spare Parts List 38 49 Drive Part IE2 for control Item Qty Unit Component number Version DESIGNATION rund...