Operation
17/49
Selection switch
Manual / Auto
Switch between
manual mode
and
automatic mode
.
Manual operation:
The plant functions can be started manually via buttons
(e.g. start of turbine or filter cleaning)
Automatic operation:
All buttons are non-functional. The system is started
remotely by a switching signal via a potential-free contact.
Filter cleaning takes place programme-controlled.
Button for manual mode
On/off switch turbine
In
manual mode
, the turbine may be manually started with
the green button. The white lamp is now active. The turbine
is stopped with the red button.
The switch has no function in
automatic mode
.
Button "emptying flap
hand"
In devices with electro-pneumatically actuated emptying
flap, this can be opened and emptied with the button in
manual mode
.
The button has no function in
automatic mode
.
Button "Filter cleaning"
Manual operation
: Manual start of filter cleaning.
See chapter "Electrical filter cleaning".
Automatic operation:
Button has no function.
Button "Acknowledge
fault"
After correcting a fault, the key must "Acknowledge fault"
are pressed around the plant to operate again
Button "Cell-wheel lock
hand"
In devices with cell wheel lock, this can be turned with this
button in
manual mode
.
The button has no function in
automatic mode
.
Содержание ID 30/30 Afc
Страница 1: ...Translation of the Original Operating Manual ID 30 30 Afc ID 50 40 Afc...
Страница 2: ...2 49...
Страница 6: ...Delivery internal transportation unpacking 6 49...
Страница 37: ...Spare Parts List 37 49 Drive Part IE2 for control...
Страница 38: ...Spare Parts List 38 49 Drive Part IE2 for control Item Qty Unit Component number Version DESIGNATION rund...