Layout and function
12/49
Technical Data /30 IE2
Power
3,0kW
3,45kW
Frequency
50Hz
60Hz
Hedging
16A
16A
Voltage/
power consumption
200-260V / 11,4A Δ
230-290V / 10,8A Δ
350-450V / 6,5A Y
400-500V / 6,2A Y
Pressure
-260 / +270mbar
-240 / +230mbar
Blower Output
315m³/h
375m³/h
Degree of protection
IP 55
of efficiency
IE2-85,5
cosφ 0,82
Technical Data /40 IE2
Output
4,0kW
4,6kW
Frequenz
50Hz
60Hz
Hedging
20A
20A
Voltage/
Power intake
350-450V / 8,4A Δ
400-500V / 8,2A Δ
610-725V / 4,8A Y
690-725V / 4,7A Y
Pressure
-140 / +130mbar
-80 / +80mbar
Air displacement volume
495m³/h
595m³/h
Protection type
IP 55
Efficiency
IE2-85,8
cosφ 0,88