– 14
Troubleshooting
Danger
To avoid risks, all repairs and replacement of spare parts may only be carried out by au-
thorized customer service personnel.
First pull out the plug from the mains before carrying out any tasks on the machine.
Fault
Cause
Remedy
Pump runs but does not
transport
Air in the pump
see chapter "Preparation" fig. A and
B and and chapter "Operations" fig.
C
Suction pipe blocked
Pull out the mains plug and clean the
suction pipe
Pre-filter is dirty
Remove the pre-filter and clean it un-
der flowing water; rinse out residual
dirt, if any, in the filter intake by open-
ing the drain.
Pump does not run or sud-
denly comes to a standstill
during operations
Power supply interrupted
Check fuses and electrical connec-
tions
The additionally used swimmer
switch has switched off the pump.
Restart the pump via the remote
control or the On/Off switch if there is
a sufficient water supply.
Thermal protection switch has
switched off the pump due to over-
heating
Pull out the mains plug, let the pump
cool down, clean the suction area,
prevent dry running
Pump switches on or off un-
expectedly
Program activated via remote control Check the remote control settings
Remote control battery is empty
Change the battery
Remote control range is exceeded or
wireless signal of the remote control
is disturbed due to wireless signals of
other devices
Reduce distance to the pump. Maxi-
mum distance to pump is 100m;
walls and other hindrances can re-
duce the range.
Pump transports is reducing
or transported quantity is
too low
Suction pipe blocked
Pull out the mains plug and clean the
suction pipe
Pre-filter is dirty
Remove the pre-filter and clean it un-
der flowing water; rinse out residual
dirt, if any, in the filter intake by open-
ing the drain.
Suction side is leaky
Check the entire suction side for
leaks
The quantity transported by the
pump depends on the transport
height and the connected periphery
Keep max. flow height, see technical
data. If necessary, select a different
hose diameter or hose length.
Our Kärcher branch will be pleased to help you further in the case of questions or faults.
See address on the reverse.
26
EN
Содержание GP 50
Страница 2: ...2...
Страница 3: ...3...
Страница 86: ...6 __U2028 86 EL...
Страница 87: ...7 3 2m 30mA 30mA VE VE B EN 60555 1 3 230V 87 EL...
Страница 89: ...9 1 2 7 89 EL...
Страница 90: ...10 1 97 2 98 30 5m PAIr ON OFF 90 EL...
Страница 91: ...11 3 98 1 59 min 4 98 1 1 5 99 2 2 5 99 1 Pr 1 6 100 2 Pr 2 6 100 91 EL...
Страница 92: ...12 CR2032 5 92 EL...
Страница 95: ...15 n Off 100m K rcher 95 EL...
Страница 96: ...16 GP 50 V 230 240 Hz 50 P W 1050 l h 4000 m 9 MPa bar 0 47 4 7 m 47 mm 1 kg 10 2 m 100 MHz 868 8 CR2032 96 EL...
Страница 97: ...1 97...
Страница 98: ...2 3 4 98...
Страница 99: ...5 99...
Страница 100: ...6 100...
Страница 101: ......