– 3
Please follow the safety instructions before
start-up!
The automatic house water system main-
tains the pressure in the mains automatical-
ly. The pump is turned on if the pressure
falls below 0.16MPa (1.6 bar). The pump
runs as long as the flow meter detects a
water extraction (flow > 200 l/h). If the water
extraction is finished, the pump is turned off
after a short trailing period. The system is
now under pressure. In the case of re-
newed water extraction and the resulting
pressure drop, the pump starts again.
The pump remains turned on for a 3 second
period (“overpump time”) after the extrac-
tion is finished to build up the required pres-
sure again. This period can be adjusted if
needed.
It should be increased if the pump is fre-
quently switched on and off (in the case of
reduced water extraction or system leak-
age).
Under ideal conditions, it can be reduced to
save energy.
Use the + / - buttons to adjust the overpump
time. The active light shows the current set-
ting (20s/10s/5s/3s).
If the pump is inactive for an extended peri-
od of time, the LEDs will switch from a con-
tinuous light to the energy conservation
mode and will then blink approx. 1 time per
minute.
A blinking LED during pump operation sig-
nals an active water flow.
1 Power cord with plug
2 Connection G1(33.3mm) Pressure pipe
3 Filling nozzle
4 Cover with prefilter and built in backflow
valve
5 Drain opening
6 Connection G1(33.3mm) Suction pipe
7 Drain cover with flow meter and safety
device
8 ON/OFF switch
9 Operation buttons
10 Overpump time indication.
Please follow the safety instructions before
start-up!
Illustration
Connect anti-vacuum suction hose with
backflow stop valve on the suction side.
(see special accessories)
Note:
Please use original Kärcher suction
lines, filter components and hose connec-
tions. If components made by other manu-
facturers are used, there can be
malfunctions when suctioning the liquid,
especially if you are using bayonet connec-
tion systems.
With fixed installations:
Connect the
pressure side to the pressure line using
a flexible pressure compensating hose
to reduce noise (see special accesso-
ries).
Tip:
To make subsequent empting of the
system and pressure release easier, we
recommend you install a shut-off valve be-
tween pump and pressure line.
(not included in delivery)
By closing the shut-off valve when empty-
ing the pump you can prevent water from
escaping from the pressure line.
Operations
System operation
Settings
Description of the Appliance
Preparing the Appliance
17
EN
Содержание BPE 4000/45
Страница 2: ...2...
Страница 3: ...3...
Страница 74: ...1 35 C REACH www kaercher com REACH EL 1 EL 2 EL 3 EL 5 EL 5 EL 5 EL 6 EL 7 EL 9 EL 11 74 EL...
Страница 75: ...2 3 2m 30mA 30mA 75 EL...
Страница 77: ...4 10 K rcher 1 4 min 77 EL...
Страница 78: ...5 Til overvintring og l ngere opbevaring 5 78 EL...
Страница 82: ...9 82 EL...
Страница 83: ...10 2 2 K rcher 83 EL...
Страница 85: ......