5
Take the dirt water discharge hose from
the support and lower above a suited
collection device.
Figure 11, see cover page
Let off water by opening the dosage de-
vice at the discharge hose.
The rinse the dirt water reservoir with
clear water.
Unscrew the filter cup of the fresh water
filter and let the fresh water tank drain
completely.
Replace the filter cup.
Check the waste container. If needed,
remove and empty waste container af-
ter work.
Turn main key to "0" and remove it.
Secure the machine with wheel chocks
to prevent it from rolling away.
DANGER
Risk of injury! When loading or unloading
the machine, it may only be operated on
gradients of max. 10%. Drive slowly.
몇
CAUTION
Risk of injury and damage! Observe the
weight of the appliance when you transport it.
When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
Remove brushes from the brush head.
몇
CAUTION
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in
interior rooms.
Select the storage site for the appliance
taking into consideration the permissi-
ble total weight of the appliance in order
not to impact its stability.
Danger
Risk of injury. Before carrying out any tasks
on the machine, set the main key to "0" and
remove it. Press emergency-stop button.
Place the appliance on a stable, even sur-
face and disconnect the battery.
몇
WARNING
Suction turbine will continue to run for a
while after switch-off. Carry out mainte-
nance tasks only after the suction turbine
has come to a halt.
Drain and dispose of the dirt water and
the residual fresh water.
ATTENTION
Risk of damage. Do not sluice the appli-
ance with water and do not use aggressive
detergents.
Drain off dirt water.
Check the flat folded filter, clean if re-
quired
Only with R cleaning head Remove bulk
waste container and empty it.
Clean the outside of the appliance with
a damp cloth which has been soaked in
mild detergent.
Clean the vacuum lips and the wiping
lips, check for wear and replace if re-
quired.
Check the brushes for wear, replace if
required.
Charge the battery:
If the charging state of the battery is un-
der 50%, charge the battery fully and
without interruption.
If the charging state of the battery is
over 50%, only recharge the battery if
the entire operation duration will be re-
quired when next used.
When used regularly, charge the bat-
tery fully and without interruption at
least once a week.
Check battery pole for oxidation; brush
it if required and lubricate it using pole
grease. Ensure that the connection ca-
ble sits firmly.
Clean the seals between waste water
tank and cover and check for tightness,
replace if required.
Check the acid density of the cells if the
batteries are not maintenance-free bat-
teries.
Clean the brush tunnel (only R cleaning
head)
Figure 12, see cover page
Remove the water distribution strip from
the cleaning head and clean water ca-
nal (only R cleaning head).
For long periods of disuse, only turn the
device off when the battery is fully
charged. Fully recharge the battery at
least every month.
Replace pump hose of the metering
pump (only Dose model).
Have the prescribed inspection carried
out by the customer service.
For a reliable operation of the appliance
maintenance contracts can be concluded
with the competent sales/service consult-
ant.
Remove the vacuum bar.
Unscrew the star grips.
Figure 13, see cover page
Remove the plastic parts.
Remove the vacuum lips.
Insert new vacuum lips.
Insert the plastic parts.
Screw in and tighten the star grips.
Push the pedal for raising/ lowering the
cleaning head down.
Slide the cleaning head under the appli-
ance so that the hose points toward the
rear.
Only slide the cleaning head halfway
under the appliance.
Figure 14, see cover page
Remove the lid of the cleaning head.
Figure 15, see cover page
Connect the power cord of the cleaning
head to the appliance (same colours
must meet).
Replace the lid and lock it.
Slide the cleaning head halfway under
the appliance.
Figure 16, see cover page
Connect the hose couplers on the
cleaning head to the hose on the appli-
ance.
Figure 17, see cover page
Insert the tab into the middle of the
cleaning head, between the fork of the
lever.
Position the lever on the pedal for rais-
ing/lowering so that the borings in the
lever and the cleaning head align.
Insert the stop pin through the bushings
and swivel the locking plate downward.
Figure 18, see cover page
Insert the cylinder pin into the boring of
the drawbar.
Slide the drawbar with the pin the guide
channel on the cleaning head all the
way to the bottom and lock.
Repeat process on the drawbar on the
opposite side.
Push the pedal for raising/ lowering the
cleaning head down.
Slide the cleaning head under the appli-
ance so that the hose points toward the
rear.
Only slide the cleaning head halfway
under the appliance.
Figure 19, see cover page
Pull out the cover.
Figure 20, see cover page
Connect the power cord of the cleaning
head to the appliance (same colours
must meet).
Push in the cover.
Slide the cleaning head halfway under
the appliance.
Figure 16, see cover page
Connect the hose couplers on the
cleaning head to the hose on the appli-
ance.
Figure 21, see cover page
Insert the tab into the middle of the
cleaning head, between the fork of the
lever.
Position the lever on the pedal for rais-
ing/lowering so that the borings in the
lever and the cleaning head align.
Insert the stop pin through the bushings
and swivel the locking plate downward.
Emptying the Fresh Water Tank
Empty waste container (only with R
cleaning head)
Shutting down
Transport
With mounted D cleaning head
Storage
Care and maintenance
Maintenance schedule
After the work
Weekly
Monthly
Yearly
Maintenance Works
Maintenance contract
Replacing the vacuum lips
Install D cleaning head
Install R cleaning head
17
EN
Содержание B 90 R Adv
Страница 2: ... 1 2 ...
Страница 3: ... 2 3 ...
Страница 4: ... 3 4 ...
Страница 240: ...http www kaercher com dealersearch ...