47
Machine powers up everything runs except the vac motor the icon is red.
1.
It is not possible to check for voltage to the vac motor if it is disconnected from the harness, the controller will put out 35
VAC. With your volt meter set on AC voltage, and the main switch in a vacuum mode, check for voltage at the vac motor
connector in the harness, is the output 35 VAC? (figure 1c)
Yes
Test the motor wires for resistance if greater than .3Ω replace the motor. If the reading is OL check the
wiring to the motor repair as needed. If the wiring is good, replace the vac motor.
No
Replace the main controller.
Figure 1c