Solution tank access
Once the tower has been removed you have access to the tank cover, and the strainer.
Old style
New style
If the solution cover has a metal plate holding part of the
cover it will leak water onto the deck if the tank is left full.
If this is the case you will need to upgrade to the new one piece
cover and gasket kit p/n 8.641-726.0. The kit on Windsor service
bulletin 16-WSB-07 includes the tank cover, seal, replacement
screws and instructions.
The strainer body can only be accessed by removing the
tower. It is important to check the solution hose from the
strainer to the tank. If it is not inserted correctly, water will
pour out of the right rear corner of the machine.