T600 Tag Tester
DOC#:
UM 360420-835
REVISION F
Page 48 of 55
© Kapsch TrafficCom Canada Inc. 2022
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence
and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for
manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: UM 360420-835 REV F, T600 OPERATOR AND MAINTENANCE MANUAL.DOCX 03/28/2022 3:02
Kapsch TrafficCom
TTU functional check
After 100 consecutive OBU tests that result in
No response from tag
, the Functional Check Requirement message
window appears (see Figure 6-1). Perform the following procedure before contacting Kapsch TrafficCom Canada Inc..
Figure 6-1: The Functional Check Requirement message
Test a known good OBU.
If the known good tag passes the test and the functional check requirement message does not appear, the TTU is
functioning properly.
If the functional check requirement message appears after testing the known good tag, test two additional
known good tags.
If the functional check requirement message appears after testing three known good tags, create a new log file
(see
, page 25), change the text in the
User/Comment
box, then retest three known good
tags.
If the functional check requirement message appears after retesting three known good tags, contact Kapsch
TrafficCom Canada Inc..
Sending Log Files to Kapsch TrafficCom Canada Inc.
The log files generated by the T600 contain important information about the tags tested. Kapsch may request theses
log files to assist in troubleshooting.
Obtain a RMA number from Kapsch TrafficCom Canada Inc.
Rename the log file to include the RMA number.
Email the log file in its original format to Kapsch TrafficCom Canada Inc.