Anti-virus protection
77
o
graphic objects less than 2 MB;
o
all other objects (except applications) less than 256 KB.
•
The maximum number of objects scanned in RAM without
saving to the working folder on the hard drive. You can set this
value in the range between 1 to 1000. The suggested default
value is 128.
•
The maximum number of objects being scanned in RAM in KB.
Select the required value from the drop-down list.
If the queue is full or if the size of the object is above the
specified limit, the object will be saved and scanned in the
work folder located n the application data folder.
All files over 1024 KB are saved to be processed in the work-
ing folder.
The values of the settings used for scanning objects in RAM
shall be determined based on the characteristics of the hard-
ware of the computer on which the Security Server is installed.
The total volume of the objects being scanned shall not ex-
ceed the amount of free RAM.
•
The size of the queue of objects to be scanned - the maximum
number of objects being scanned and waiting to be scanned in
the working folder on the hard drive. You can set this value in
the range between 1 to 16383. The suggested default value is
1024.
If the queue is full, an object will not be scanned, but will be
classified as clean and sent to the client that requested this
object.
•
The maximum time for scanning one object (in seconds).
Specify the value within the range from 0 to 86400 seconds
(inclusive). The default value is 1800 seconds.
If the object could not be scanned within the specified time
period, it will be classified as clean and sent to the client that
requested this object.
In order to exclude containers from the scan scope, check the
Do not
scan containers with nesting level above
box and enter the desired
value (the default value is 32). The application will scan all nested objects
within the container including the specified level.