Chapter 7 - Commands and Messages
54
DBldisc
ON|OFF
default ON
When OFF, only one disconnect command (
D
) need be sent to terminate an unsuccessful con-
nect sequence. When ON, a normal disconnect sequence will always occur.
DElete
n
default $08 (
)
This command sets the character to be used as the Delete character.
DIDdle
ON|OFF
default OFF
When ON, a diddle character is sent when no characters are available from the keyboard or
buffer during transmission in RTTY or ASCII Mode. In RTTY the diddle character is the LTRS char-
acter, in ASCII the diddle character is a null.
DIGipeat
ON|OFF
default ON/ON
When ON, any packet received that has
MYcall
or
MYAlais
in the digipeat list of its address field
will be retransmitted. Each station included in the digipeat list relays the packet in the order speci-
fied in the address field. Digipeating takes place concurrently with other unit operations and does
not interfere with normal connected operation of the station. To disable digipeat operations turn
this command OFF. This command is valid only while the KAM is in Command Mode or packet op-
eration. Selection of CW, RTTY, ASCII or AMTOR Modes disables
DIGipeat
.
Disconnect
This command will initiate an immediate disconnect request with the currently connected sta-
tion. A succesful disconnect results in the display of
***DISCONNECTED
.
If multiple connects exist, the Disconnect command will disconnect the station on the stream
to which I/O is currently addressed.
Other commands may be entered while the disconnect is in progress. If the
RETry
count is ex-
ceeded while waiting for the connected station to acknowledge, the KAM moves to the discon-
nected state on that stream.
Disconnect messages are not displayed when the unit is in Transparent Mode.
DISPlay
This command causes the unit to display a list of all the parameters of the unit. You may also
display only selected parameters by affixing the appropriate class identifier for that group. Sub-
classes of related parameters are:
(L)ink
parameters affecting packet, link
(A)sync
asynchronous port parameters
(C)haracter
special characters
(I)d
ID parameters
(M)onitor
monitor parameters
(T)iming
timing parameters
(X)t
parameters of non-packet modes only
Individual parameter values can be displayed by entering the
DISPlay
command followed by
the parameter name. When using the
DISPlay
command with either a subclass or individual pa-
rameter name, be sure to use a space between them. Display classes are illustrated preceding the
response messages section of this manual.