11
6666----2 Position of the needle guard (front)
2 Position of the needle guard (front)
2 Position of the needle guard (front)
2 Position of the needle guard (front)
■
The needle guard (front) should be 1.5~2mm above
the point of the left needle when the point of the
looper has reached the center of the left needle.
The clearance between the needle guard (front) and
the left or right needle when the point of the looper
has reached the center of the left or right needle
should be 0.1~0.3mm.
■
To adjust the height of the needle guard (front),
loosen screw A and set the distance from the point of
the left needle to the needle guard (front) when the
point of the looper has reached the center of the left
needle at 1.5~2mm.
■
To adjust the needle guard (front) front to back,
loosen screws A and B and set the clearance
between the needle guard (front) and the left or
right needle when the point of the looper has
reached the center of the left or right needle at
0.1~0.3mm.
< Note >
Retighten the screws while checking there is no
left-to-right shake on the needle guard (front).