OPERATION MANUAL
AF INTEGRA / AF-H INTEGRA ELT
PAGE: 102
JUN 20/2013
The red light gives an indication on the working mode of the beacon:
• after the self test:
- a series of short flashes indicates the self test failed;
- one long flash indicates a correct self test;
• in operating mode:
- periodic flashes during 121.5 transmission;
- long flash during 406 transmission.
A buzzer gives audio information on the beacon working:
• continuous tone during self test;
• 1 beep every 0.7 second during 121.5 transmission;
• silence during 406 transmission.
C. Working mode information
The ELT has 4 different modes:
• Off.
• Self-test (temporary mode).
• Armed (standby mode to enable automatic activation by the shock sensor
or by an optional remote control panel).
• On (transmission).
Transmission is effective if the beacon is activated (either manually on the ELT
control panel, automatically by the shock sensor, or remotely by the "ON"
switch of an optional remote control panel when connected).
(1)Off
The ELT is off when the switch is in position "OFF", no part of the ELT
is energized.
This mode must only be selected when the ELT is removed from the
aircraft or when the aircraft is parked for a long period or for
maintenance.
(2) Self-Test
The self-test mode is a temporary mode (max duration 15 sec) in which
the ELT checks the main characteristics of the transmitter (Battery
voltage, Programming...) and enables digital communication with
programming and test equipment.
This mode is selected:
• when switching from "OFF" to "ARM";
• when switching to "RESET / TEST" on an optional Remote Control
Panel (provided that the switch of the ELT is in position "ARM");
• when switching to "ON" prior to transmission.
Содержание AF INTEGRA
Страница 30: ...OPERATION MANUAL AF INTEGRA AF H INTEGRA ELT PAGE 112 JUN 20 2013 PAGE INTENTIONALLY LEFT BLANK ...
Страница 38: ...OPERATION MANUAL AF INTEGRA AF H INTEGRA ELT PAGE 208 JUN 20 2013 PAGE INTENTIONALLY LEFT BLANK ...
Страница 42: ...OPERATION MANUAL AF INTEGRA AF H INTEGRA ELT PAGE 304 JUN 20 2013 PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...OPERATION MANUAL AF INTEGRA AF H INTEGRA ELT PAGE 402 JUN 20 2013 PAGE INTENTIONALLY LEFT BLANK ...
Страница 51: ......