4.5 ROOM CO TESTING
Select “Room CO” to measure and record CO readings for up to 30 minutes.
SELECT
→
ROOM CO
→
TEST TYPE
→
GENERAL
→
Use
/
to select the test type from
the following:
TEST TYPES
GENERAL:
15 minute test with results
stored every minute
LIMIT = 10ppm
ALARM = 30 ppm
SWEEP TEST:
2 minute test with max reading
stored at end
LIMIT = 10ppm
ALARM = 30 ppm
MIGRATION TEST:
15 minute test with results
stored every minute
LIMIT = 10ppm
ALARM = 30 ppm
TYPE C SEALED APPLIANCE: 15 minute test with results
stored every minute
LIMIT = 10ppm
ALARM = 30 ppm
TYPE B BOILER OPEN FLUE:
15 minute test with results
stored every minute
LIMIT = 10ppm
ALARM = 30 ppm
TYPE A COOKER:
30 minute test with results
stored every miute
LIMIT = 30ppm
ALARM = 90 ppm
TYPE A WATER HEATER:
5 minute test with results
stored every minute
LIMIT = 10ppm
ALARM = 30 ppm
TYPE A SPACE HEATER:
30 minute test with results
stored every 1 minute
LIMIT = 10ppm
ALARM = 30 ppm
Press
/
to start Room CO testing.