4. USING THE ANALYSER:
4.1 COMBUSTION TESTS:
Insert the tip of the flue probe into the centre of the flue. The readings will stabilise
within 60 seconds assuming the boiler conditions are stable.
The rotary switch can be used to display the following information:
RATIO Display
NAT GAS
→
Fuel type can be changed via “Menu”.
R 0.0008
→
CO/CO
2
ratio.
CO
52p
→
Carbon monoxide (ppm).
CO2
6.3%
→
Carbon dioxide (%).
XAIR
88.7
→
Excess air %
PRS
0.01m
→
Pressure reading
Press
/
to print a full combustion test, (or send to PC via optional
Wireless module).
Hold
/
for 2+ seconds to log a full combustion report.