29
KANE 358 MANUAL
Calculations
Carbon Dioxide
0 - 20%
0.1%
±0.3% Volume
Oxygen
0 - 21%
0.1%
±0.3% Volume
CO/CO2 Ratio
0 - 0.9999
0.0001
±5% of reading
Efficiency (Net or Gross)
0 - 99.9%
0.1%
±1% of reading
Efficiency High (C)
0 - 119.9%
0.1%
±1% of reading
Excess Air
0 - 119.9%
0.1%
±0.2% of reading
Pressure (Differential)
±80mbar
0.1mbar
±0.5% FSD
Pre-programmed Fuels
UK, USA & France
Natural Gas, Propane, Butane, LPG, Light Oil, Digester Gas, Wood
Pellets
European
Natural Gas, Light Oil, Bio Oil, Coke, LPG, Wood, Town Gas, Butane
& Propane
Battery Life
>8 hours (continuous with pump on)
Certification
The KANE358 is independently tested and certified to EN 50379,
Parts 1-3 in accordance to 1st German Federal Emission Control
Ordinance (BimschV)
SPECIFICATIONS
PARAMETER
RANGE
RESOLUTION
ACCURACY
Temperature Measurement
Flue Temperature
0 - 600°C
0.1°C
±0.5°C
Inlet temp
Internal Sensor
0 50°C
0.1°C
±1°C
Inlet temp
External Sensor
0 - 600°C
0.1°C
±0.5°C
Flue Gas Measurement
Carbon Monoxide
0 - 2000ppm
1ppm
±3ppm or ±5% of reading
whichever is greater
Carbon Dioxide
0 - 20%
0.1%
±0.3% Volume
Oxygen
0 - 21%
0.1%
±0.3% Volume