COMMISSIONING
4
To commission the generator, follow the maintenance recommendations for the first month or twenty hours of
operation (whichever comes first) contained in the “Maintenance” section.
For commissioning models with elektrostart please charge the battery. Please use additional battery charger (not
included) to charge the battery or let the generator work at least one hour at 50% load at the first start.
The manufacturer reserves the right to make changes in the prod-
uct design, configuration and construction. Illustrations in this
manual are for reference only and may differ from actual compo
-
nents and inscriptions on the products.
IMPORTANT!
1. Voltmeter or
LED display
2. Safety switch
3. Outlets
4 . Engine start button (ON/OFF)
5.
12V/8A DC outlet
6. Ground connector
1. Fill the crankcase with engine oil. The recommended amount of oil for each model is indicated in the specification
chart.
2. Check oil level with an oil dipstick. It should be between the MIN and MAX marks on the oil dipstick.
3. Check fuel level.
4. Check the air filter for correct installation
In the first 20 operating hours of the generator, the following requirements should be met:
1. During commissioning, do not connect power consumers, the power of which exceeds 50% of the nominal
(operating) power of the device.
2. After the first 20 operating hours, be sure to change the oil. It is better to drain oil while the engine is still hot after
operation to ensure quick and complete oil draining.
3. Check and clean the air filter, fuel filter and spark plug.
CHECK THE FUEL LEVEL
CHECK THE FUEL LEVEL
1. Wear protective gloves to avoid getting gasoline on your skin.
2. Unscrew the fuel cap and check the fuel level in the tank.
3. Fill the fuel tank to the fuel filter level.
4. Tighten the fuel cap securely.
CHECK THE OIL LEVEL
CHECK THE OIL LEVEL
Recommended fuel:
Unleaded gasoline.
Fuel tank volume
: see specifications table.
Recommended engine oil:
SAE 10W-30, SAE 10W-40.
Recommended engine oil grade:
API Service SE type or higher.
Motor oil quantity:
see specifications table.
1. Wear protective gloves to avoid getting oil on your skin.
2. Unscrew the oil dipstick and wipe it out with a clean cloth.
3. Insert the dipstick without screwing it in.
4. Check the oil level by a mark on the oil dipstick.
5. Add oil if its level is below the mark on the oil dipstick.
6. Tighten the oil dipstick.
Only unleaded gasoline is recommended for the generator. The
use of leaded gasoline will cause severe damage to internal engine
parts.
IMPORTANT!
fill to here
STARTING TO WORK
5
1
2
3
6
5
4
konner-sohnen.com
|