background image

  

  

CLEANING THE FILTER:

CLEANING THE FILTER:

1.  Open the air filter cover.

2. Remove the sponge filtering element.
3.  Remove all dirt deposits inside the hollow case of the air filter.
4.  Thoroughly wash the filtering element in warm water.
5. Dry the sponge filter.
6.  Dry filtering element is to be moistened by machine oil and excess oil 

is to be squeezed out.

GENERATOR STORAGE

10

The generator must be stored in a dry, well-ventilated area that is free from dust. Keep away from children and 

animals.

Generator should always remain ready for operation. Therefore 

in case of device malfunctions, they are to be repaired before dis-

mounting the generator for storage.

IMPORTANT!

  

  

GENERATOR LONG-TERM STORAGE

GENERATOR LONG-TERM STORAGE

If the generator will not be used for a long time, it is recommended to:

- Drain the fuel into the tank.

- Drain the motor oil.

- Pull the manual starter until a slight resistance is felt so that the inlet and drain valves get closed.

- Clean the generator from dirt and dust.

When starting the generator after long-term storage, proceed as above in the reverse order.

GENERATOR TRANSPORTATION

11

GENERATOR AND BATTERY UTILISATION

12

WARRANTY SERVICE TERMS

13

For easy generator transportation use packaging, which generator was sold in. Secure the box with the generator to 

avoid tipping it on the side of the carriage. Before moving the generator drain the fuel and disconnect the terminals 

of the battery (if this model has a battery).

To move the generator from one place to another lift it by holding the frame (if generator has construction with open 

frame). If generator has an silent cover, use transportation handles. Be careful, do not expose your feet under the 

generator.

To prevent damage to the environment separate generator and battery from ordinary waste and recycle them in the 

safest way passing a special place for disposal.

Potential faults and troubleshooting methods, as well as average device capacities can 

Potential faults and troubleshooting methods, as well as average device capacities can 

be found in thefull version of the manual.

be found in thefull version of the manual.

The international manufacturer warranty is 1 year. The warranty period starts from the date of purchase. In cases when warranty 

period is longer than 1 year according to local legislation please contact your local dealer. The Seller which sells the product is 

responsible for granting the warranty. Please contact the Seller for warranty. Within the warranty period, if the product fails because 

of defects in the production process, it will be exchanged on the same product or repaired.

All faults caused by the manufacturer during the warranty period will be eliminated free of charge. Warranty repair is carried out 

only if you have a fully completed warranty card, the Buyer’s signature of acceptance of the warranty terms, as well as a document 

supporting the purchase (cash receipt, sales slip or invoice). In the absence thereof, as well as in the event of errors or corrections 

not authenticated by the seller’s seal or illegible inscriptions in the warranty card or tear-off coupon, no warranty repair is carried 

out, no objections to quality are accepted and the warranty card is withdrawn by the service center as invalid. The device is accepted 

for repair clean and full.

konner-sohnen.com

   

|

    8

Содержание KSB 30A

Страница 1: ...Please read this manual carefully before use OWNER S MANUAL GASOLINE GENERATOR KSB 30A KSB 70C EN...

Страница 2: ...r safety shoes and gloves We care about the environment therefore we consider it expedient to savepaper and We care about the environment therefore we consider it expedient to savepaper and leave in p...

Страница 3: ...rical rules and regulations Connect the generator to the protective ground before operation Wires with damaged or spoiled insulation should be replaced You should also replace worn damaged or rusty co...

Страница 4: ...10 420 Voltage regulator AVR AVR Engine start manual manual Power factor cos 1 230V 1 230V Dimensions LxWxH mm 605x440x435 690x525x550 Net weight kg 36 2 66 6 Protection class IP23M IP23M Max altitude...

Страница 5: ...ng do not connect power consumers the power of which exceeds 50 of the nominal operating power of the device 2 After the first 20 operating hours be sure to change the oil It is better to drain oil wh...

Страница 6: ...er the generator start WARNING DANGER Before starting the engine make sure that the total power of tools or power consumers corresponds to the rated power of the generator Do not exceed the rated powe...

Страница 7: ...and technical maintanance rules IMPORTANT If the generator is often working at high temperature or at high load the oil should be replaced every 25 operating hours If the engine is often running in du...

Страница 8: ...PLUG TECHNICAL MAINTENANCE 8 Spark plug SPARK PLUG INSPECTION SPARK PLUG INSPECTION 1 Remove the cap from the spark plug 2 Remove the spark plug by means of a corresponding spanner 3 Examine the spark...

Страница 9: ...ion with open frame If generator has an silent cover use transportation handles Be careful do not expose your feet under the generator To prevent damage to the environment separate generator and batte...

Страница 10: ......

Страница 11: ...de Kundendienst technische Fragen Kundendienst technische Fragen und Unterst tzung und Unterst tzung support dimaxgroup de Garantie Reparatur und Service Garantie Reparatur und Service service dimaxgr...

Отзывы: