Works, specified in “Technical maintenance” section, are to be regularily performed. If the the generator user has 

no possibility to perform regular maintenance independently, it is necessary to address the official service center to 

registrate an order for such works performance.
You can find a list of service center addresses in your warranty card.

MAINTENANCE

6

  

  

STOPPING THE ENGINE

STOPPING THE ENGINE

1. Disconnect all power consumers from the generator, set the safety switch to the OFF position.

2. Allow the generator to operate at idle for 3 minutes so that the alternator cools down.

3. In case of manual start, set the engine switch to OFF.

4. In case of electric start, set the key to OFF.

5. Move the fuel valve to the “CLOSE” position.

DISCONNECT ALL THE DEVICES BEFORE STOPPING THE GENERATOR! 

Do not stop the generator, if there are connected devices. This may 

lead generator down!

WARNING - DANGER!

1. Move the fuel valve to the “OPEN” position.

2. Set the air choke to the closed position.

3.  To start the generator manually, grasp the starter handle and slowly pull it until resistance is felt. Pull the starter 

cord to the full length with a sharp movement.

4. Set the air choke to the “OPEN” position.

  

  

ENGINE START

ENGINE START

Do not connect two or more devices simultaneously. The start-up 

of many devices requires high power. Devices should be connected 

in turn according to their power rating. Do not connect any power 

consumers within the first 3 minutes after the generator start.

WARNING - DANGER!

Before starting the engine 

make sure that the total power of tools or power consumers corresponds to the 

rated power of the generator. Do not exceed the rated power of the generator. 

Do not connect any devices 

before the engine start! In the power supply mode, the generator should operate no longer 

than 30 minutes in the range from rated to maximum power.

Before connecting any devices to the generator, make sure that they are in good condition. If the device that was 

connected suddenly stopped or failed, immediately disconnect the power using a safety switch, disconnect the 

device and check it out.

Fuel valve

 Air choke

closed

OPEN

open

CLOSE

Closed 

Open

Hand starter

If the generator has not been used for a long time, recharge the 

battery with a charger (not included).

IMPORTANT!

Standby generators should not run continuously (e.g. by adding 

fuel to the tank or connecting a large fuel tank) or longer than 

recommended: 4-6 hours for gasoline generators (depending on 

load).

ATTENTION – DANGER!

This material is for informational purposes only and does not constitute a manual for installing the equip-

ment or connecting it to the mains, but we strongly recommend that you read the instructions below. 

Equipment connection must always be carried out by a certified electrician responsible for the installation 

and electrical connection of the equipment according to local laws and regulations. The manufacturer 

assumes no liability for improper connection of the equipment or for any material or physical damage that 

may result from improper installation, connection or operation of the equipment.

fill to here

konner-sohnen.com

   

|

    5

Содержание KSB 30A

Страница 1: ...Please read this manual carefully before use OWNER S MANUAL GASOLINE GENERATOR KSB 30A KSB 70C EN...

Страница 2: ...r safety shoes and gloves We care about the environment therefore we consider it expedient to savepaper and We care about the environment therefore we consider it expedient to savepaper and leave in p...

Страница 3: ...rical rules and regulations Connect the generator to the protective ground before operation Wires with damaged or spoiled insulation should be replaced You should also replace worn damaged or rusty co...

Страница 4: ...10 420 Voltage regulator AVR AVR Engine start manual manual Power factor cos 1 230V 1 230V Dimensions LxWxH mm 605x440x435 690x525x550 Net weight kg 36 2 66 6 Protection class IP23M IP23M Max altitude...

Страница 5: ...ng do not connect power consumers the power of which exceeds 50 of the nominal operating power of the device 2 After the first 20 operating hours be sure to change the oil It is better to drain oil wh...

Страница 6: ...er the generator start WARNING DANGER Before starting the engine make sure that the total power of tools or power consumers corresponds to the rated power of the generator Do not exceed the rated powe...

Страница 7: ...and technical maintanance rules IMPORTANT If the generator is often working at high temperature or at high load the oil should be replaced every 25 operating hours If the engine is often running in du...

Страница 8: ...PLUG TECHNICAL MAINTENANCE 8 Spark plug SPARK PLUG INSPECTION SPARK PLUG INSPECTION 1 Remove the cap from the spark plug 2 Remove the spark plug by means of a corresponding spanner 3 Examine the spark...

Страница 9: ...ion with open frame If generator has an silent cover use transportation handles Be careful do not expose your feet under the generator To prevent damage to the environment separate generator and batte...

Страница 10: ......

Страница 11: ...de Kundendienst technische Fragen Kundendienst technische Fragen und Unterst tzung und Unterst tzung support dimaxgroup de Garantie Reparatur und Service Garantie Reparatur und Service service dimaxgr...

Отзывы: