MULTICAL® 803 & ULTRAFLOW®
1 In general
Please read this guide carefully before installing the energy meter.
In case of incorrect mounting, Kamstrup's guarantee obligations no longer apply.
By connecting to 230 V supply, there is a risk of electric shock.
When working on the flow sensor in the installation, there is a risk of outflow of (hot)
water under pressure.
At a media temperature higher than 60 °C, the flow sensor should be shielded from
unintended contact.
Please note that the following installation conditions must be obeyed:
- Pressure stage ULTRAFLOW®:
PN16/PN25, see marking
- Pressure stage Kamstrup sensor pair, type DS:
PN16/PN25
- Pressure stage Kamstrup pocket sensors, type PL: PN25
At media temperatures above 90 °C, we recommend flange sensors as well as wall-mounting of
MULTICAL®.
At media temperatures below the ambient temperature, MULTICAL® must be wall-mounted, and
the flow sensor/ULTRAFLOW® must be a condensation-proof version.