55

3.  Power supply

MULTICAL

®

 61 can be powered by means of a built-in lithium battery or 24 VAC or 

230 VAC mains supplied via an integral supply module.
The two cables from battery or supply module are mounted in the calculator’s 
terminal strip.
 

 The polarity must be correct: 

red cable to terminal no. 60 (+)
black cable to terminal no. 61 (-)

3.1 Battery supply

MULTICAL

®

 61 is connected to a lithium battery, D-cell. The battery is marked with 

installation year, e.g. 2009 as well as production date.
Kamstrup type number: 66-00-200-100.
Optimal battery lifetime is obtained by keeping the battery temperature below 30°C.
The voltage of a lithium battery is almost constant throughout the lifetime of the 
battery (approx. 3.65 V). Therefore, it is not possible to determine the remaining 
capacity by measuring the voltage.
The battery cannot and must not be charged and must not be short-circuited!
Used batteries must be handed in for approved destruction, f.inst. at Kamstrup A/S.

3.2 Supply modules

The modules are protection class II and are connected via a two-
wire cable (without earth) through the cable bush of the calculator 
placed in the right side of the connecting base. 
Use connecting cable with an outer diameter of 5-10 mm and 
ensure correct dismantling as well as correct cable relief.
Max. permitted fuse: 6A
National regulations for electric installations must be observed. 

Black

Red

Black

Red

24 VAC

A transformer must be used, e.g. type 
66-99-403 for 24 VAC supply module.
Note!  This module cannot be supplied 

by 24 VDC.

230 VAC

For direct mains connection.

Содержание MULTICAL 61

Страница 1: ...Installation and User Guide for MULTICAL 61 Cold Water Meter www kamstrup com...

Страница 2: ...170K Temperaturf lers t 10 C 150 C 3K 140K Flowm ler 15 C 130 C Mekanisk milj M1 fast installation med minimal vibration Elektromagnetisk milj E1 og E2 bolig let industri og industri M lerens signalka...

Страница 3: ...Kamstrup A S Industrivej 28 Stilling DK 8660 Skanderborg TEL 45 89 93 10 00 FAX 45 89 93 10 01 info kamstrup com www kamstrup com MULTICAL 61 Cold Water Meter English I N S T A L L A T I O N...

Страница 4: ...wer supplies can be added The utility can replace communication module and battery If greater distance is required up to 10 m between flow sensor and display unit a PULSE TRANSMITTER type number 66 99...

Страница 5: ...t proper tightening of the sealing surface and that PN10 glands are used PN16 glands gaskets can be used When the installation has been completed water flow can be turned on The valve on the inlet sid...

Страница 6: ...ng is mounted on the flow sensor type no 3026 252 is ordered separately The cable must be mounted minimum 25 cm from other electric installations Do not forget to seal the calculator Important ULTRAFL...

Страница 7: ...lifetime of the battery approx 3 65 V Therefore it is not possible to determine the remaining capacity by measuring the voltage The battery cannot and must not be charged and must not be short circui...

Страница 8: ...RS232 level requires connection of data cable 66 99 106 D Sub 9F or 66 99 098 USB with the following connections 62 Brown DAT 63 White REQ 64 Green GND The pulse inputs can be used for connection of...

Страница 9: ...mains supply 5 1 4 Prog data logger RTC 4 20 mA inputs pulse inputs 67 00 22 The module has connection possibility for two pressure transmitters on terminals 57 58 and 59 and can be adjusted for curre...

Страница 10: ...nals are not used in this module Type 67 05 RTC data output hourly data logger The module has a galvanically separated data port which functions with the KMP protocol The data output can be used for e...

Страница 11: ...e for volume pulses for water meters The pulse resolution follows the display fixed in the CCC code E g CCC 419 Q3 1 6 m3 h 1 pulse 0 01m3 The pulse outputs are optoisolated and withstand 30 VDC and 1...

Страница 12: ...k adjustment Configuration of pulse outputs Base module Data pulse inputs 10 Pulse values of VA and VB are changed via METERTOOL M Bus pulse inputs 20 Pulse values of VA and VB are changed via METERTO...

Страница 13: ...ription Response time 0 No irregularities 1 Supply voltage has been interrupted 16 Flow meter V1 communication error signal too weak or wrong flow direction After reset e g cover off and on as well as...

Страница 14: ...hange battery or check mains supply No display function empty display Power supply missing Change battery or check mains supply Is there 3 6 VDC on terminals 60 and 61 If info 1 Supply voltage has bee...

Страница 15: ...by current time Target date displayed as month and day In this example 1 June The calculator s serial number The program number of the calculator Followed by configuration codes DDD EE and FFF GG M N...

Страница 16: ...rtant functions If there is a serious error in measuring system or installation a flashing info will appear in the display until the error has been corrected The Info field flashes as long as the erro...

Отзывы: