29
Kamstrup A/S • 55122714_A2_GB_04_2021
flowIQ® Gateway
8 Operation
8.1 Normal operation
In operation mode, all communication modules are on. If a radio communication module is
plugged in, it will send data at the specified interval. flowIQ® Gateway can at all times be accessed
via the front keys, through the optical interface via READy App or METERTOOL HCW.
In normal operation, the user display loop is available for checking the current readings and status
of flowIQ® Gateway and attached devices.
The synchronization between the flowIQ® 2200/3200 meter and flowIQ® Gateway is done every 20
seconds.
8.2 Alarms and info codes
flowIQ® Gateway constantly monitors a number of important functions.
If an alarm/info code is triggered in the connected flowIQ® 2200/3200
meter, it is forwarded to flowIQ® Gateway. When an alarm/info code is
active, a flashing “INFO” appears in the display. As long as the alarm/
info code event is active, the display keeps flashing “INFO”. When the
event that has triggered the alarm/info code has been fixed, the “INFO”
field in the display automatically stops flashing.
You can find information about the current “INFO” event by scrolling to position 8 in the display.