9
Kamstrup A/S • 55123307_A1_EN-US_06.2022
Installation guide flowIQ® 4200
4.3.1 General flange features and specifications
Fixing bolt ¼” bolt and nut:
The fixing bolt thread is useful for connecting the two split flange parts during installation.
Pushing nut milling:
If extra space for the gasket is needed, insert a 7/16” nut in the pushing nut milling,
and insert a 7/16” bolt from the opposite side to press and enlarge the gap between the
flanges, thus creating space for the gasket.
Lifting lugs
The lifting lugs have two purposes:
• Supporting safe conduct regarding meter installation when lifting
• Fixating the split flanges on the meter