Kamstrup A/S • 55123307_A1_EN-US_06.2022
Installation guide flowIQ® 4200
3.4 Flow direction
The meter has an arrow on the side of the meter, indicating the right flow direction
through the meter. Only this direction is legal. If flow is registered in the wrong direction,
the info code ‘REVERSE’ is visible in the display, which means that the meter detects
reverse flow. The meter calculates the volume in a separate register not verified for
billing. Reverse volume is NOT displayed on the meter.
4 flowIQ® 4200 installation
A flowIQ® 4200 meter is delivered with separate coated split flanges in cast iron.
Furthermore the 6” and 8” variants of the meter are delivered with spool pieces.
Use only the original split flanges and spool pieces from Kamstrup combined with
original fiber gaskets. Gaskets can be ordered separately.
flowIQ® 4200
Warning!
Only lift the meter by using the lifting lugs.