17.2
Yearly, Monthly and daily loggers
The table below shows which registers are logged on the first day of the month/year, and which registers logged
every day. The logger is an absolute log, i.e. current meter reading, logged every day.
Register type
Description
Yearly
logger
10 years
Monthly
logger
36 months
Daily
logger
460 days
Date (YY.MM.DD)
Logging time, year, month and day
✓
✓
✓
Volume V1
Current meter reading (legal)
✓
✓
✓
Operating hour counter
Accumulated number of operating hours
✓
✓
✓
Info
Info code
–
✓
✓
Vol Reverse
Volume during reverse flow
✓
✓
–
Date for max flow
Date stamp of max flow during period
✓
✓
–
**Max flow V1
Value for max flow during period
✓
✓
✓
Date for min. flow V1
Date stamp of min. flow during period
✓
✓
–
Min. flow V1
Value of min. flow during period
✓
✓
✓
*Min water temp.
The lowest measured water temperature
during period
✓
✓
✓
*Average water temp.
Volume weighted average water
temperature during period
–
✓
✓
*Max water temp.
The highest measured water
temperature during period
✓
✓
✓
Min. ambient/meter
temp.
The lowest measured ambient
temperature during period
✓
✓
✓
Average ambient/meter
temp.
Time weighted average ambient
temperature during period
–
✓
✓
Max ambient/meter
temp.
The highest measured ambient
temperature during period
✓
✓
✓
*
Applies only for meter sizes 1.6, 2.5 and 4.0 m
3
/h
‘Max flow’ is f
or water meter size:
1.6 - 16 m³/h always shown in l/h
25-100m³/ h, always shown in m³/h (2 decimals) - from this SW revision and forward:
SW rev.: T1 (wireless M-bus),
G1(wired M-bus)
1.6-63 m³/h Sigfox always in l/h
Every time an info code changes, date and code are logged. Thus, it is possible to read the last 50 changes of the
information codes and date of the change. The reading is only possible via the optical eye.
For the following modules: 60, 61, 62, 63, 64, 65 and 99 the daily, monthly and yearly loggers are not accessible
from the optical eye, which is why the values in the loggers will be cero (showing a
‘
0
’
).