51
Kampmann Assembly and Installation Instructions - UniLine Cassette Door Air Curtains
Electrical wiring | UniLine EC, KaControl model (*C1)
10.12. Parameter settings
10.12.1 Setting of absolute setpoint temperature or ± 3K
Parameter P36
It may be necessary in office or hotel applications for the system operator to
specify a base setpoint. The user has the option of changing the setpoint
temperature by ± 3K to even out any different perception of room
temperature.
Alternately the setpoint can be set in absolute values.
Parameter P36 is used to configure the setpoint setting.
Use parameter P01 to configure the base setpoint for the "Setpoint setting
3K” version.
Position
P36
Setpoint setting
0 = Absolute setpoint setting
1 = Setpoint setting ± 3 K
Position
P01
Base setpoint for setpoint setting ± 3K
Parameter P36
Setting of “absolute” setpoint temperature
Parameter P36=1
Setpoint temperature setting ± 3K
When the parameters are being set
P37=1 Display setpoint temperature
P36=1 Setpoint setting ± 3K
no setpoint is shown in the default display!