Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual
23
3.4.1 Continuous mode liquid level detection
1. Liquid level detection:
liquid level detection switch, if the liquid level detection switch is
turned on, when the pump is running, if there is a liquid level alarm, the pump stops running;
2. Level alarm type:
The level float has two states 0 and 1, which are used to adapt different level
sensors and different float sensors. If 0 is selected, the machine recognizes that the float status is 0.
Alarm and stop the motor. If 1 is selected, the machine recognizes the alarm when the float state is
1, and stops the motor.
3.5 Ration mode
In the ration mode, there are two working modes, namely a fully automatic working mode
and a semi-automatic working mode;
1. Semi-automatic working mode:
the user sets a working quantity in this mode, and clicks
the start button to work. When the working quantitative running is finished, the pump
automatically stops working, clicks the start button again, the pump runs a certain quantity and
stops automatically;
2.fully automatic working mode:
set a job quantitative, pause time, target work times, click
the start button to run, the pump will follow the work to complete a certain amount, then pause for
a period of time, then work a certain amount of such a loop work, when the cycle works After the
number of times the target has been reached, the pump stops working.